Beijing Reci Laser Technology Co., Ltd
User Guide for Single Module Fiber Laser
30
Figure 4.8 the connecting for remote AD model
(1) Set the AD mode with the control software.
(2) The 24V remote start signal is connected to pins 3 and 4 in the rear panel 16
PIN CTRL_INTERFACE.
(3) The 24V laser enable signal is connected to pins 5 and 6 of the rear panel 16
PIN CTRL_INTERFACE.
(4) The 24V modulated signal is connected to pins 12 and 13 in the rear panel 16
PIN CTRL_INTERFACE.
(5) Connect 0~10V analog signal to pins 14 and 15 in the rear panel 16 PIN
CTRL_INTERFACE.
4.7.2
Sequence of operations
(1) Turn the front panel key switch to the REM side.
(2) Turn on the power switch at Rear panel of device. Wait for 10s to initialize
the
device. (It can also be closed and opened, controlled by an external switch.)
(3) Turn on the 24V remote start signal, power on the laser power module, and
the red light indicator turns on.
(4) Set the optical power through the 0~10V analog signal.
(5) Turn on the 24V laser enable signal. (After 3 seconds, the remote start signal
can be set to enable the laser output power to be changed after the laser is
enabled.)
(7)Fast switching optical modulation output by modulation signal. (The red light