Isolating Switching Amplifier
N-132
8.3
Installation
8.3.1 Electrical Connections
8.3.2 Schematic Diagrams
See device labelling.
8.3.3 Connection of Supply
DANGER
Explosion hazard caused by voltage that is too high!
Non-compliance results in severe or fatal injuries.
• Connect the device only to equipment with internal voltage U
m
:
max. 253 V AC.
• Connect the device only to intrinsically safe terminals.
DANGER
Explosion hazard due to incorrect safety characteristic values of the
device or connected field devices!
Non-compliance results in severe or fatal injuries.
• Check safety characteristic values of the device and connected
field devices according to the national installation guidelines.
Device type
Type of supply
Connection
N-132/1-10
N-132/2-10
N-132/1-E-10
N-132/2-E-10
Direct supply of the device via 24 V connection Green terminal "7+" and "9-"
N-132/1-01
N-132/2-01
Direct supply of the device via 230 V connection Green terminal "L" and "N"