Technical Data
Electrical version
4 wire DC
Output function
Analogue
Operating voltage (U
B
)
15...30 V DC
Permitted residual ripple max.
5 %
Load resistance (R
L
)
≤ 200 Ω (≥ 2 KΩ)**
Power consumption max. (outputs no-load)
0.9 W
Analogue output
4...20 mA (0...10 V)**
Permitted ambient temperature
-25...+70 °C
Permitted ambient temperature (for probe with temperature
buffer (TP) between non-active range IBS and IBH
-25...+200 °C**
LED-Display
Green
Protective circuit
Built-in
Degree of protection IEC 60529
IP 67
Norm
EN 60947-5-2*
Connection cable
2 m, PVC, 5 x 0.34 mm²
*Where applicable. For further technical data: see data sheet
** Dependent on type
Electrical connection
LED green / Output Adjustment
Adjustment Min.
Adjustment Max.
Factory set
Test
Electrical connection:
• Disconnect the system from all power.
• Connect the probe according to the connection diagram.
• Switch power on.