Version Number: RBM-1350 20210712A2
13
CABLE
Position
Checking keys
Remarks
Torch
cable
If torch cable over bended.
If the metal connecting point of
mobile plug loosen.
Cause poor wire sending.
Unstable arc if cable over bended.
Output
cable
Wearing-out of the cable insulated
material.
Cable connecting head
naked(insulation damage),or
loosen(the end of power supply, and
cable of main material connecting
point.)
For life security and stable welding, adopt
suitable method to check according to
working place.
Simple check daily
Careful and in-depth check on fixed period
Input
cable
If the connect of power supply input,
protective equipment input and the
output end fixed or not.
If the security equipment cable
reliably connected.
If the power input end cable fixed.
If the input cable is worn out and
bares the conductor.
Earth
cable
If the earth cable that connects the
power supply is broken and connect
tightly.
If the earth cable that connects the
main part is broken and connects
tightly.
To prevent creep age and insure security,
please make daily check.