Version Number: RBM-1350 20210712A2
12
Part 6 Daily maintenance and checking
Daily maintenance
a) Remove dust regularly with dry compressed air. If the welding machine is used in surroundings with heavy
smoke and polluted air, it is necessary to remove dust at least one time one month.
b) Examine inside electric joints and ensure perfect contact (Especially plugs and sockets). Fasten the loosing
joints. In case of oxidation, remove oxide film with sand paper and connect again.
c) Prevent water from entering into the machine and prevent the machine from getting moist. If any, blow and
dry. Measure the insulation with megohmmeter to make sure it is qualified to use.
d) If the welding machine is not used for a long time, pack the machine in original package and store in dry
surroundings.
e) Every time the wire feeder operates for 300hours, grind the electrical carbon brush and clear up the
armature commutator. Rinse speed reducer, apply 2# Molybdenum Disulfide lubricant to the turbine,
whirlpool rod and bearing.
All the maintenance and testing must be carried out when the power supply is totally cut off. Please
make sure the power is off before opening the closure.
Daily checking
WELDING TORCH
Position
Checking keys
Remarks
Loophole
If installment fixed, the front distorted Reason for air hole.
Attach splash or not.
Reason for burning the torch.
(
can use splash-proof material
)
Electric
hole
If installment fixed
Reason of torch screw thread damage
Damage of its head and hole blocked
nor not
Reason of unstable arc and broken arc
Wire
sending
tube
Check the extended size of the pipe
Have to be changed when less than 6mm,
when the extended part too small, the arc will
be unstable.
Wire diameter and the tube inner
diameter match or not
Reason of unstable arc, please use the
suitable tube.
Partial winding and extended
Reason of poor wires sending and unstable
arc, please change.
Block caused by dirt in the tube, and
the remains of the wire plating lay.
Reason of poor wire sending and unstable arc,
(use kerosene to wipe or change new one.)
Wire sending tube broken O circle
wear out
1.Pyrocondensation tube broken, change new
tube
2.Change new O circle