background image

RTL8812AE 

Half Mini-Card User Manual

 

 

                                                                                            

5                                                           

                            Rev.1.0

 

 

 

3.3.

 

Warning  

3.3.1 Federal Communication Commission Interference Statement 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant 

to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful 
interference in a residential installation.  This equipment generates, uses and can radiate radio frequency energy 
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio 
communications.  However, there is no guarantee that interference will not occur in a particular installation.  If 
this equipment does cause harmful interference to radio or television reception, which can be determined by 
turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following 
measures: 
 

Reorient or relocate the receiving antenna. 

Increase the separation between the equipment and receiver. 

Connect the equipment into an outlet on a circuit different from that 

to which the receiver is connected. 

Consult the dealer or an experienced radio/TV technician for help. 

 
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) 
This device may not cause harmful interference, and (2) this device must accept any interference received, 
including interference that may cause undesired operation. 
 
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance 
could void the user's authority to operate this equipment. 
 
IMPORTANT NOTE: 
FCC Radiation Exposure Statement: 
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This 
equipment should be installed and operated with minimum distance 20cm between the radiator & your body. 
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 
 
Operations in the 5.15-5.25GHz band are restricted to indoor usage only.

 

IEEE 802.11b or 802.11g operation of this product in the U.S.A. is firmware-limited to channels 1 through 11. 
 
This device is intended only for OEM integrators under the following conditions: 
1.)The antenna must be installed such that 20 cm is maintained between the antenna and users, and  
2.)The transmitter module may not be co-located with any other transmitter or antenna,  
3.)For all products market in US, OEM has to limit the operation channels in CH1 to CH11 for 2.4G band by 
supplied firmware programming tool. OEM shall not supply any tool or info to the end-user regarding to 
Regulatory Domain change. 
 
As long as 3 conditions above are met, further transmitter test will not be required. However, the OEM 
integrator is still responsible for testing their end-product for any additional compliance requirements required 
with this module installed (for example, digital device emissions, PC peripheral requirements, etc.). 

Summary of Contents for RTL8812AE

Page 1: ...Mini Card User s Manual Rev 1 0 29 November 2012 Realtek Semiconductor Corp No 2 Innovation Road II Hsinchu Science Park Hsinchu 300 Taiwan Tel 886 3 578 0211 Fax 886 3 577 6047 www realtek com tw RTL8812AE ...

Page 2: ...d or changes in this document or in the product described in this document at any time This document could include technical inaccuracies or typographical errors TRADEMARKS Realtek is a trademark of Realtek Semiconductor Corporation Other names mentioned in this document are trademarks registered trademarks of their respective owners USING THIS DOCUMENT This document is intended for the software e...

Page 3: ...TURES 1 3 PRODUCT SPECIFICATIONS 3 3 1 ENVIRONMENTAL 3 3 1 1 Operating 3 3 1 2 Storage 3 3 2 FUNCTIONAL SPECIFICATIONS 3 3 3 WARNING 5 3 3 1 Federal Communication Commission Interference Statement 5 3 3 2 Industry Canada Statement 6 3 3 3 NCC 警語 7 List of Tables TABLE 2 FUNCTIONAL SPECIFICATIONS 3 ...

Page 4: ...ed to support all IEEE 802 11b 802 11g and 802 11a data rates Differential phase shift keying modulation schemes DBPSK and DQPSK with data scrambling capability are available and CCK provides support for legacy data rates with long or short preamble The high speed FFT IFFT paths combined with BPSK QPSK 16QAM 64QAM and 256QAM modulation of the individual subcarriers and rate compatible coding rate ...

Page 5: ...ocol efficiency Using packet aggregation techniques such as A MPDU with BA and A MSDU protocol efficiency is significantly improved Power saving mechanisms such as Legacy Power Save U APSD and MIMO power saving reduce the power wasted during idle time and compensate for the extra power required to transmit MIMO OFDM The RTL8812AE provides simple legacy 20MHz 40MHz 80MHz co existence mechanisms to ...

Page 6: ...MM IEEE 802 11i WPA WPA2 Open shared key and pair wise key authentication services IEEE 802 11h TPC Spectrum Measurement IEEE 802 11k Radio Resource Measurement WAPI Wireless Authentication Privacy Infrastructure certified Cisco Compatible Extensions CCX for WLAN devices MAC Features Frame aggregation for increased MAC efficiency A MSDU A MPDU Low latency immediate High Throughput Block Acknowledg...

Page 7: ...s Sounding packet DSSS with DBPSK and DQPSK CCK modulation with long and short preamble OFDM with BPSK QPSK 16QAM 64QAM and 256QAM modulation Convolutional Coding Rate 1 2 2 3 3 4 and 5 6 Maximum data rate 54Mbps in 802 11g 300Mbps in 802 11n and 866 7Mbps in 802 11ac OFDM receive diversity with MRC using up to 2 receive paths Switch diversity used for DSSS CCK Support STBC Support LDPC Hardware a...

Page 8: ...EEE 802 11a b g n e i h k r draft ac Bus Interface PCI Express Form Factor Half Size Mini Card Data Rate 802 11b 11 5 5 2 1 Mbps 802 11g 54 48 36 24 18 12 9 6 Mbps 802 11n MCS 0 to 15 for HT20MHz MCS 0 to 15 for HT40MHz 802 11ac MCS 0 to 8 for HT20MHz MCS 0 to 9 for HT40MHz MCS 0 to 9 for HT80MHz Media Access Control CSMA CA with ACK Modulation Techniques 802 11b CCK DQPSK DBPSK 802 11a g n 64 QAM...

Page 9: ...00 104 108 112 116 120 124 128 132 136 140 Ch 149 153 157 161 165 40MHz band width Ch 38 46 Ch 54 62 Ch 102 110 118 126 134 Ch 151 159 80MHz band width Ch 42 Ch 58 Ch 105 122 Ch 155 Frequency Range 2 400GHz 2 4835 GHz 5 1500GHz 5 3500GHz 5 4700GHz 5 7250GHz 5 7250GHz 5 8500GHz Security WPA WPA PSK WPA2 WPA2 PSK WEP 64bit 128bit IEEE 802 11x IEEE 802 11i Operating Voltage 3 3 V 9 I O supply voltage...

Page 10: ...ived including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment IMPORTANT NOTE FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be i...

Page 11: ...manual shall include all required regulatory information warning as show in this manual 3 3 2 Industry Canada Statement This device complies with RSS 210 of the Industry Canada Rules Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device This...

Page 12: ...t including the transmitter and obtaining a separate IC authorization End Product Labeling The final end product must be labeled in a visible area with the following Contains IC 6317A RTL8812AE Manual Information That Must be Included The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove This RF module in the user s manual of the end produ...

Page 13: ...12AE Half Mini Card User Manual 8 Rev 1 0 Realtek Semiconductor Corp Headquarters No 2 Innovation Road II Hsinchu Science Park Hsinchu 300 Taiwan R O C Tel 886 3 5780211 Fax 886 3 5776047 www realtek com tw ...

Reviews: