background image

18

Possible Cause: Burner ports are clogged or blocked.

 

-Clean burner ports. Do this by inserting a

 

paperclip into each of the burner ports to

 

ensure they are not clogged. WARNING: Make

 

sure burner is not on and the gas supply has

 

been properly disconnected. Allow 15 minutes

 

for unit to cool completely before touching it.

If  these  troubleshooting  steps  are  unable  to  resolve  the  problem, 

please call Real Flame at: 1-800-654-1704

Possible Cause 1: High or gusting winds.

 

-Increase fl ame to “HIGH” setting.

Possible Cause 2: Low on LP gas.

 

-Replace or refi ll LP gas tank.

Possible Cause 3: Excess fl ow valve tripped.

 

-Refer to “Problem: Sudden drop in gas fl ow”

Possible Cause 1: Ice has built up on the outside of the LP gas tank because the

    vaporization process is too low.

 

-Turn the control knob and the LP gas tank to “OFF”. Replace with a spare LP

 

gas tank and resume burning. Store the spare LP gas tank in a well ventilated

 

area, away from children.

Possible Cause 1: Out of gas.

 

- Refill or exchange your LP tank.

Possible Cause 2: Excess fl ow safety device may have been activated.

 

-

 if the flame goes out. In order for the unit to work flames must be contacting the 

 thermocouple located in the igniter housing. Visually inspect the thermocouple and 

 igniter housing to make sure there are no obstructions, such as lava rock or glass filler

 and that flames are contacting the thermocouple. 

 

 

Problem: Sudden drop in gas fl ow, or a reduced fl ame height

Problem: Irregular fl ame pattern, fl ame does not run the full length of the burner

Problem: Flame blow out

Problem: Flame seems to lose heat when burning in cold weather -

temperature below 50°F

Burner Ports

Troubleshooting

Summary of Contents for 42100140

Page 1: ...this equipment Save these instructions for future reference If you are assembling this unit for someone else give this manual to him or her to read and save for future reference Designed and Engineer...

Page 2: ...tent car or home Important Safety Information Propane LP Gas Dangers and Warnings Hose and Regulator Assembly and Replacement Parts List Assembly Instructions Lighting Care and Cleaning Gas Component...

Page 3: ...s and be kept at a safe distance while fire table is in use This outdoor fire table is NOT to be operated by children Young children should be closely supervised when in the vicinity of this outdoor f...

Page 4: ...5 m of this outdoor fire table while it is in operation DO NOT use this outdoor fire table near automobiles trucks vans or recreational vehicles DO NOT use this outdoor fire table under any overhead s...

Page 5: ...d manufacturer warranty LP GAS LP gas is flammable and hazardous if handled improperly Become aware of the characteristics before using any LP gas product Propane Characteristics Flammable explosive u...

Page 6: ...f contained LP gas system of a camper trailer motor home or house Always use the pressure regulator and hose assembly provided with the appliance to connect to a LP gas cylinder Never connect to an un...

Page 7: ...table as per lighting instructions 2 Be sure to protect the hose from any hot surfaces Serious danger may result if the hose contacts any hot surface 3 Regular maintenance of the hose and regulator a...

Page 8: ...0lb 66450999 AA Battery N A 7 8 9 10 1 Table Top LMST 115624796A WSLT 115624396A Table Base LMST 115624796B WSLT 115624396B Glass Panels 49510991 Feet 95600931 2 3 4 5 11 Touch up Paint 75oz WSLT LMST...

Page 9: ...ble if filler is wet Ensure filler is completely dry before lighting Intense heat can cause wet filler to explode and hit someone causing injury 3 Please keep away from the fire table for at least 20...

Page 10: ...l the AA battery as shown in the diagram below a Place the tank seat on the ground and place a 20lb propane tank into the tank seat a Tighten down the screw on the side of the tank seat to secure the...

Page 11: ...knob clockwise Hand tighten only Make sure the valve on the LP gas tank is OFF Disconnect by turning the knob counter clockwise until it is detached from the valve 5 Connecting the LP Gas Tank Discon...

Page 12: ...indicated by arrows If any bubbles appear turn LP gas tank OFF reconnect and retest If you continue to see bubbles after several attempts disconnect LP gas source and contact Real Flame at 1 800 654 1...

Page 13: ...0 Adjust the flame to the desired height with the control knob WARNING If burner flame goes out during operation immediately turn the control knob OFF and let the gas clear a minimum of 5 minutes befo...

Page 14: ...ents for any signs of damage rust or excessive wear 5 If damage to any component is detected DO NOT operate until the proper repairs have been made ARNING cool to the touch General Care and Cleaning W...

Page 15: ...rode wire is correctly and completely connected 2 Make sure that the igniter housing is unobstructed between the igniter pin thermocouple and the burner tube Igniter Housing Burner Tube Do not block o...

Page 16: ...ouple Wire Wire should be in line with valve Valve 5mm Thermocouple Igniter Pin Gas Component Connection Checks 3 Make sure that the igniter pin and thermocouple are correctly positioned The igniter p...

Page 17: ...e Cause 3 Igniter Pin cracked or broken sparks at crack Call Real Flame at 1 800 654 1704 for technical support Possible Cause 4 Wire loose or disconnected Reference page 15 step 1 reconnect wire Call...

Page 18: ...the vaporization process is too low Turn the control knob and the LP gas tank to OFF Replace with a spare LP gas tank and resume burning Store the spare LP gas tank in a well ventilated area away from...

Page 19: ...damaged either by the manufacturer or in shipping you may request a replacement within 30 days of receipt Replacement parts are not available for all units and only given at Real Flame s discretion W...

Page 20: ...eone else give this manual to him or her to read and save for future reference DANGER WARNING PO _______________ Makena Natural Gas Fire Table Owner s Manual Rectangle Style 42100283 42100140 For Tech...

Page 21: ...s Troubleshooting 3 5 7 8 9 10 11 13 14 15 17 CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this appliance in...

Page 22: ...to the hazards of high surface temperatures and be kept at a safe distance while fire table is in use This outdoor fire table is NOT to be operated by children Young children should be closely superv...

Page 23: ...utdoor fire table DO NOT use this outdoor fire table until it is COMPLETELY assembled and all parts are securely fastened and tightened DO NOT store another LP gas tank within 10 feet 3 05 m of this o...

Page 24: ...l Gas must be used on all male pipe threads Apply compound or tape to at least the first three to four threads when making a connection Important Safety Information Continued Prior to each fire table...

Page 25: ...ral Gas Connection The outdoor fire table must be isolated from the gas supply piping system by closing the least equal to or less than 1 2 psi 3 5 kPa Warning Burner valves are pre tested at the fact...

Page 26: ...e LMST 115624777B WSLT 115624377B Glass Panels 49510991 Feet 95600931 NG Hose and Quick Connect Lava Rock 20lb 66450999 AA Battery N A 2 3 7 8 9 4 5 10 10 Touch up Paint 75oz WSLT LMST 49490991 494909...

Page 27: ...table if filler is wet Ensure filler is completely dry before lighting Intense heat can cause wet filler to explode and hit someone causing injury 3 Please keep away from the fire table for at least 2...

Page 28: ...ons 4 Connecting your fire table to the Natural Gas Source socket is recommended by the National Fuel Gas Code Socket connection must be made outdoors The diagram below shows the main components of a...

Page 29: ...be connected to the fire table Direction of gas flow is indicated on the socket 6 Using the Quick Connect Socket Pull back the sleeve on the quick disconnect socket and insert the unattached end of th...

Page 30: ...s s a G l a r u t a N t c e n n o c s i d s t p m e t t a l a r e v e s contact Real Flame at 1 800 654 1704 for assistance If no bubbles appear after one minute turn source OFF wipe away solution an...

Page 31: ...knob WARNING If burner flame goes out during operation immediately turn the control knob OFF and let the gas clear a minimum of 5 minutes before attempting to relight the fire table After lighting ro...

Page 32: ...excessive wear 5 If damage to any component is detected DO NOT operate until the proper repairs have been made ARNING cool to the touch General Care and Cleaning W DO NOT use oven cleaner or abrasive...

Page 33: ...not light or stay lit please perform the following checks CORRECT INCORRECT Igniter Housing Burner Tube Do not block opening Gas Component Connection Checks 1 Make sure the electrode wire is correctly...

Page 34: ...ermocouple should be positioned 5mm away from the burner tube 4 Make sure that the thermocouple wire is correctly positioned The thermocouple wire should be in line with the valve Thermocouple Wire Wi...

Page 35: ...Check if Natural Gas supply is stopped If it is not stopped refer to Problem Sudden drop in gas flow on the following page Possible Cause 2 Quick Connect not fully engaged Disconnect the quick connect...

Page 36: ...the Natural Gas connection Problem Irregular flame pattern flame does not run the full length of the burner Possible Cause Burner ports are clogged or blocked Clean burner ports Do this by inserting a...

Page 37: ...damaged either by the manufacturer or in shipping you may request a replacement within 30 days of receipt Replacement parts are not available for all units and only given at Real Flame s discretion W...

Reviews:

Related manuals for 42100140