CMT106 IDE controller utilityModule
5
Real Time Devices USA, Inc.
Chapter 3
INSTALLING THE UTILITYMODULE
Since the utilityModule uses a PC/104 stackthrough bus, the only hardware installation you will
do is placing the module to the PC/104 stack. To do this, you will connect the PC/104 bus
connector with the matching connector of another module.
Recommended Procedure
We recommend you follow the procedure below to ensure that stacking of the modules does not
damage connectors or electronics.
•
Turn off power to the PC/104 system or stack.
•
Select and install standoffs to properly position the utilityModule on the PC/104 stack.
•
Touch a grounded metal part of the stack to discharge any buildup of static electricity.
•
Remove the utilityModule from its anti-static bag.
•
Check that keying pins in the PC/104 bus connector are properly positioned.
•
Check the stacking order: make sure an XT bus card will not be placed between two AT bus
cards, or it will interrupt the AT bus signals.
•
Hold the utilityModule by its edges and orient it so the bus connector pins line up with the
matching connector on the stack.
•
Gently and evenly press the utilityModule onto the PC/104 stack.
CAUTION: Do not force the module onto the stack! Wiggling the module or applying too
much force may damage it. If the module does not readily press into place,
remove it, check for bent pins or out-of-place keying pins, and try again.
User’s Manual
Summary of Contents for CMT106
Page 6: ...Features CMT106 IDE controller utilityModule 2 Real Time Devices USA Inc...
Page 8: ...Jumpers CMT106 IDE controller utilityModule 4 Real Time Devices USA Inc...
Page 10: ...Recommended Procedure CMT106 IDE controller utilityModule 6 Real Time Devices USA Inc...
Page 16: ...Power Protection Circuitry CMT106 IDE controller utilityModule 12 Real Time Devices USA Inc...