WARRANTY INFORMATION

The benefits provided to you under the following warranty are in addition to any other rights and remedies available to

you under the law.

1. Warranty

If:
(a)

during the first 12 months from the date of purchase (Burner Warranty Period) there is a defect in the Real Flame

gas burner; or

(b) during the first 12 months from the date of purchase (Parts Warranty Period) there is a defect in the gas valves or

other parts of the Real Flame Pit Fire, due to improper workmanship or material, Real Flame will replace or repair

the Real Flame Gas Burner without charge. Any replacement product is warranted only for the time remaining on

the original Burner Warranty Period or the Parts Warranty Period as relevant.

2. Registration

You must register to receive the benefit of this warranty by completing the warranty registration on our website

(www.realflame.com.au) or completing and mailing the attached registration card within 30 days of purchase of

your Real Flame Gas Burner (or, if the Real Flame Gas Burner is fitted to a new home, within 30 days of the date

of settlement of purchase of such new home).

3. Exclusions

Real Flame is not obliged to replace or repair the Real Flame Gas Burner under clause 1 if: 

(a)

it has been improperly stored, installed, connected, used, operated or repaired, or damaged, abused, tampered

with, altered (without our written approval), or not maintained in strict accordance with our installation and

operating instructions; or

4. Limit of Liability

The warranty provided under this warranty is limited to replacement or repair of the Real Flame Gas Burner only,

at our option. To the extent permitted by law, Real Flame excludes liability for consequential loss or any other loss

or damage caused to property or persons arising from any cause whatsoever, and damage arising from normal

wear and tear.

5. Claiming under the Warranty

In order to claim under this warranty you must, within the Burner Warranty Period or the Parts Warranty Period (as

relevant), contact Real Flame, providing the original proof of purchase and the details below:

Supplier Name___________________________________________________________________________
Date Of Purchase / settlement of property if new home _________________
Model / Serial Number_______________________
This warranty does not cover the cost of claiming under the warranty or transporting the Real Flame Gas Burner to and

from the supplier.

Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a

replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage.

You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure

does not amount to a major failure.

If you would like to speak to someone about your Real Flame Gas Burner or claiming under this warranty, please

contact the Real Flame Service Warranty Desk on 03 8706 2000.

Real Flame Pty Ltd ACN 006 311 155
Head Office: 1340 Ferntree Gully Road, Scoresby 3179
Telephone: 03 8706 2000  Facsimile: 03 8706 2001

Summary of Contents for PIT FIRE SERIES

Page 1: ...t Fire series are suitable to be installed into a masonry or fireproof base in outdoor installations only Designed to operate on Natural or LPG gases only Approval no GMK10130 Installed primarily as a decorative appliance Not certified as a Space Heater VERSION 10 ...

Page 2: ...ructions or 4 Limit of Liability The warranty provided under this warranty is limited to replacement or repair of the Real Flame Gas Burner only at our option To the extent permitted by law Real Flame excludes liability for consequential loss or any other loss or damage caused to property or persons arising from any cause whatsoever and damage arising from normal wear and tear 5 Claiming under the...

Page 3: ...ondition and is not covered by warranty 3 IMPORTANT SAFETY NOTICES DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE DO NOT USE OR STORE FLAMMABLE MATERIAL NEAR THE APPLIANCE DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILST IT IS IN OPERATION DO NOT MODIFY THIS APPLIANCE THIS APPLIANCE IS DESIGNED TO OPERATE WITH LUMINOUS FLAMES THIS MAY EXHIBIT SLIGHT CARBON DEPOSITS THIS IS A NORM...

Page 4: ...5 Dimensions 6 Installation instructions 7 Wiring Diagrams 14 Commissioning procedure 16 Media Installation 17 Operation User Instructions 20 Troubleshooting 20 Conversion details 21 Parts List 22 Real Flame contact information 24 4 ...

Page 5: ... 0 95kPa 80 LPG 2 40mm 2 60kPa 80 OFRT600x400 Gas Injector Size mm TPP N G C Mj Hr Natural Gas 3 30mm 0 90kPa 53 LPG 1 75mm 2 60kPa 44 OFRT800x400 Gas Injector Size mm TPP N G C Mj Hr Natural Gas 4 00mm 0 85kPa 75 LPG 2 40mm 2 40kPa 75 OFSQ450 Gas Injector Size mm TPP N G C Mj Hr Natural Gas 3 30mm 0 90kPa 53 LPG 1 75mm 2 60kPa 44 OFSQ600 Gas Injector Size mm TPP N G C Mj Hr Natural Gas 4 00mm 0 9...

Page 6: ...ANGE DIAMETER HEIGHT OFRD500 560mm 450 OFRD700 760mm 450 OFRT600 X 400 660 460 450 OFRT800 X 400 860 460 450 OFSQ450 510 510 450 OFSQ600 660 660 450 6 Diameter Height Width Height Height Length Length Width 61 5 62 24 3 29 8 62 0 30 ...

Page 7: ...tilation without stagnant areas where gas leakage and products of combustion are rapidly dispersed by wind and natural convection Any enclosure in which the appliance is used shall comply with the following An enclosure with walls on all sides but at least one permanent opening at ground level and no overhead cover Within a partial enclosure that includes an overhead cover and no more than two wal...

Page 8: ...rger Where valve assembly cannot be reached a manhole access panel may be required All appliances must have an isolation gas valve fitted accessible and external to the appliance enclosure Construction of Enclosure INSTALLATION INSTRUCTIONS continued 8 Example 3 Example 5 Both ends open Example 4 Open side at least 25 of total wall area 30 or more in total of the remaining wall area is open and un...

Page 9: ...in residence or nearby switch enclosure wired to appliance must be installed where appliance can be viewed Wet areas Air pressure switch located near enclosure with air line back to controller Must be specified at time of ordering Drainage holes at base of enclosure are required for water runoff 150mm clearance underneath valve box is required for ventilation The gas control must not be located lo...

Page 10: ...en Power Isolation Switch on nearby wall Power Isolation Switch on nearby wall Minimum 750mm INSTALLATION INSTRUCTIONS continued Examples of enclosures Minimum 750mm Drainage hose to garden Access panel 300x400 Isolation valve Vents x 2 10 ...

Page 11: ...0 X 400 520 870 560 910 OFRD500 Diam 577 Diam 620 OFRD700 Diam 977 Diam 1019 A B D B A C 11 INSTALLATION INSTRUCTIONS continued Optional Glass Surrounds Note When installing the optional glass surrounds to your pit fire use the B and C dimensions for centre to centre measurements for 5mm pilot hole ...

Page 12: ...Power Isolation Switch on nearby wall If the finished burner height is lower than 750mm from ground level an optional glass surround must be ordered and fixed with the fixing brackets supplied Available glass heights are 200mm and 400mm Access panel 300x400 Isolation valve 750mm 400mm See notes on next page regarding gas cylinder 12 ...

Page 13: ... be opened without the use of tools An easily removable cover is also acceptable Accessibility of cylinder valve a Cylinders should be installed on a firm level non combustible base and not resting on soil The floor or base should be constructed so that water cannot accumulate within any enclosure or recess b Cylinders should not be stacked on top of each other c Any cylinder that is liable to acc...

Page 14: ...er vent EG 73mm x 150mm or larger Warranty requirement The enclosure must be constructed on a stable surface The weight of the appliance must be supported by the pan not by the control box The appliance must be installed level The interior of the enclosure must not be filled with any media Keep all area around tray and valve enclosure free and well ventilated LPG gas cylinders must not be stored i...

Page 15: ... with this appliance are supplied to the customer and the customer is trained on how to operate the appliance correctly Do not modify the appliance Do not exceed maximum rated pressures Appliance must be installed with gas installation code AS NZS5601 1 2013 and applicable electrical installation code AS3000 Test for gas leaks prior to operating appliance Check gas pressures and adjust if incorrec...

Page 16: ...d Brown Spark Spark Flame sensing S GND V 24V F FL LED 24V GND Gas Valve Blue Orange TH PSW MV PV Green Yellow Green Yellow Wiring Connection 24V wiring by installer WALL MOUNTED TRANSFORMER PACK 240 24V Orange Orange On Off Switch CNE DIRECT SPARK IGNITION MODULE CCA 0835 3333L1012 Optional 24v Wall mounted transformer kit Warning Improper installation adjustment alteration or lack of maintenance...

Page 17: ...ON Fill tray with media or until all burners tubes are covered by one layer of media Spread evenly around tray Do not cover pilot area Do not overfill with media above the pilot cover level Warning new or wet media may cause spitting of hot material from the fire and may present a burns risk Warning New rock media or wet media should be fired for approx 45 minutes prior to normal use to prevent un...

Page 18: ...her flame Do not use any other media than as supplied and recommended by the manufacturer Use of other media may result in explosive media which may cause injury or damage Do not cover or block pilot cap ventilation holes Glazed pebbles Fill tray with volcanic rock the rock level reaches the bottom of the burner tubes Lay glass media on top of volcanic rock until burner tubes are covered by one la...

Page 19: ...ox 45 minutes prior to normal use to prevent unwanted spitting A safe distance of 5 metres should be observed during this period Do not overload with media and smother flame Do not use any other media than as supplied and recommended by the manufacturer Use of other media may result in explosive media which may cause injury or damage NOTE Appliance incorporates a live fuel effect and is designed t...

Page 20: ... may cause spitting of hot material and steam from the fire and may present a burns risk or personal injury risk Maintain a safe distance of 5metres minimum until media is adequately dried or burnt off This may take up to 45 minutes of operation Note Both children and adults should be alerted to the hazards of high temperature surfaces and open flames A safe distance should be maintained to preven...

Page 21: ...th no gas leaks 10 Remove pilot assembly and replace with correct gas type 11 Reattach valve assembly Ensure connections are tight with no gas leaks 12 Reattach pilot assembly tubes and wires 13 Remove Natural gas regulator spring from valve 14 Replace regulator spring with correct gas type spring 15 Refit assembly to enclosure 16 Connect gas to inlet connection 17 Check for gas leaks 18 Fill tray...

Page 22: ...PARTS LIST 1 Valve 2 SIT Pilot assembly Natural gas SIT Pilot assembly Propane 3 Injector Natural gas Injector ULPG 4 Gas controller CNE CCA 0835 1 3 2 4 22 ...

Page 23: ...CHEMINEE PTY LTD EMAIL sales cheminee com au WEBSITE www Cheminee com au PHONE 02 9564 2694 FAX 02 9569 8802 SHOWROOM 118 Stanmore Road Stanmore Corner Wemyss St NSW ...

Reviews: