12
1.
Remove connection fitting from control valve and replace with 3/8˝ male x 1/2˝ male hex
nipple.
2.
Fit regulator to hex nipple.
3.
Fit 1/2˝ male x 1/2˝ copper union regulator.
4.
Remove pilot assembly cover and remove pilot assembly disconnecting thermocouple
pilot tube and electrode lead and replace with natural gas pilot assembly and reconnect.
5.
Remove main burner injector by loosening grub screw in boss and removing injector stem
holder from boss and change to correct size natural gas injector.
CONVERSION DETAILS
PROPANE TO NATURAL GAS
Description
PART No.
1
3/8˝ male x 1/2˝ male Hex Nipple
05
2
1/2˝ SC-75 Regulator
02
3
1/2˝ male x 1/2˝ Copper Union
04
4
Natural gas Oxy Pilot Assembly
03N
5
Natural gas Main Burner Injector
010
(Refer to data plate for correct size)
Parts Required
Procedure
1.
Remove regulator complete with 1/2˝ connection and 3/8˝ x 1/2˝ hex nipple from control
valve.
2.
Fit 3/8˝ male x 1/2˝ copper union directly into control valve.
3.
Remove pilot cover and pilot assembly disconnecting thermocouple, pilot tube and
electrode lead and replace with L.P.G. pilot assembly and reconnect.
4.
Remove main burner injector by loosening grub screw in boss and removing injector stem
holder from boss and change to correct size L.P.G. injector.
NATURAL GAS TO PROPANE
Description
PART No.
1
3/8˝ male x 1/2˝ Copper Union
-
2.
LPG Oxy Pilot Assembly
03P
3.
Main Burner Injector
010
(Refer to data plate for correct size)
Parts Required
Procedure