12
NOTE
: If the top light remains green while the bottom light
alternately flashes red and green, this indicates a temperature
abnormality (i.e. That the battery pack is either too hot or too
cold).if there is only a red blinking light, this indicates that
something is wrong with the battery .
5. A fully discharged pack with an internal temperature in
the normal range will fully charge in the 2.5 to 3
hours( between 30
°
F/0
°
C and 113
°
F/45
°
C). Heavily
cycled battery packs may take longer to charger
completely.
6. If the charging light indicator alternately blinks red and
green or the light indicator does not come on at all, check
that the battery pack is fully seated into the bay ,Remove
the pack and reinsert .
7. When charging is complete, remove the battery form the
charger by sliding the battery up to unlock it from the
charger. (Fig 13)
8. Timely recharging of the battery will help prolong the
battery’s life. You must recharge the battery pack when
you notice a drop in the equipment’s power.
IMPORTANT!
Never allow the battery pack to became
fully discharged as this will cause irreversible damage to the
battery.
Charging a Hot or Cold Battery Pack
A red and green flashing indicator light on the charger
indicates that the battery pack temperature is outside the
charging range. Once the pack is within the acceptable
range,normal charging will take place and the red light will
be continuous. Hot or cold battery packs may take longer to
charge.
Operation
三
IMPORTANT!
This pressure washer is equipped
with a micro-switch sensitive to water flow. This Total
Stop System (TSS) senses water flow in the
pump.When the trigger is released, water stops flowing
through the pump . The TSS then automatically turns
the motor off to protect the pump from
overheating,thus saving energy and prolonging pump
life.
The TSS system will work only when there’s water in the
bucket or the base unit is connected with a water supply.
When there’s no water connected with the unit, the
On/Off button has to be pressed to stop the unit.
IMPORTANT!
This system is capable of
producing 8Mpa. To avoid rupture and injury, do not
operate this pump with components rated less than 8Mpa
working pressure (including but not limited to spray
guns, hose, and hose connections).
1. Open the battery compartment cover and slide the
battery in until it click to lock it into position, then
close the battery compartment cover (Fig 14).
Lithium-Ion Charging Status
Battery Pack
Temperature
Red Charger
Indicator Light
Charging
Status
Too hot
Flashing
Not charging
Normal range
Continuous
Normal charging
Too cold
Flashing
Not charging