![Reach RT-PoE3NL/8 Manual Download Page 21](http://html1.mh-extra.com/html/reach/rt-poe3nl-8/rt-poe3nl-8_manual_1424853021.webp)
Reach PoE Tester Manual V1.4
02/15/2018
Page 21
A.3
Error messages
All error messages begin with the "!" exclamation mark.
Error Message
Description
!Syntax error
There was syntax error in the previous command.
!Reach PoE Tester...
There is an internal version error in this unit.
! invalid port value
The value given with the port prefix was not
valid.
! invalid group value
The value given with the group prefix was not
valid.
! run calibration first
If the power-on calibration was interrupted, and
the set or class commands are used, this error
message is generated.
! invalid class value
The CLASS command argument is not 0 thru 4.
! Error: set limit is 880mA
The argument for the SET command is too large.
(See
Appendix C.2
for current limits.)
!p%d Autocal FAIL
Auto-calibrate has failed on the specified port.
! unsupported baud rate
Baud rate argument is invalid
! invalid arguments
Command argument(s) are invalid
(other messages)
There are other messages that begin with an
exclamation point that are internal errors. If these
appear, the unit needs to be repaired.