Appendix A - Operational Notes
A.1
Power-on
When the unit is powered on, it performs a self-calibration of its dynamic class and
power loads. This takes around 105 seconds. While calibrating, the unit flashes the front
panel LED and displays the following. The prompt "
RT-PoE3N>
" indicates that the unit
is ready for commands.
RT-PoE3N>”(revision dependent version string)”
Calibrating all ports..
:p1 Autocal OK
:p2 Autocal OK
:p3 Autocal OK
:p4 Autocal OK
:p5 Autocal OK
:p6 Autocal OK
:p7 Autocal OK
:p8 Autocal OK
RT-PoE3N>
A.2
High power testing including IEEE 802.3at
The inrush delay mandated by IEEE 802.3at requires that a high power load (over
400mA) cannot be applied until after the 80mS inrush period. The “auto” command
enforces this inrush delay.