Re TL01-A User Manual Download Page 13

Re

  S.p.A. 

 

TL01-A

 

 

03/07/12

  

 

10/13 

 

Electrical characteristics 

ƒ

 

Power 

supply 

     12÷24Vdc. 

 

ƒ

 

Analog output :  

 

 

 

 

0÷5Vdc;  0÷10Vdc (optional). 

ƒ

 

CCD sensor :   

 

 

 

 

format 2048 square pixels 0,014 x 0,014 mm 

ƒ

 

High reading speed :   

 

 

 

>1000 times per sec. (cycle time=1msec) 

ƒ

 

Communication with regulator through LIN serial 

ƒ

 

High reliability. Use of programmed logic (CPLD)  

ƒ

 

Long illumination time  

ƒ

 

Protected against polarity inversions and short circuits  

ƒ

 

Protected against ESD (in compliance with EN61000-4-2) 

ƒ

 

Complies with EN61000-6-2 (2005) and EN61000-6-3 (2007) 

 
 

 

Other characteristics 

ƒ

 

Viewing area :   

 

 

 

 

28mm                                                      

ƒ

 

Adjustable reading area :   

 

 

1-28mm 

ƒ

 

EMD (Micrometrical Electronic Movement) : 

0,1mm 

ƒ

 

No line/edge indication by switching on a red LED               

ƒ

 

Sturdy and compact :   

 

 

 

dimensions  80 x 50 x 60mm (L x P x H) 

ƒ

 

Response time  : 

 

 

 

 

1msec  

ƒ

 

Working temperature range : 

 

 

0÷60°C      

ƒ

 

Degree of protection :  

 

 

 

IP40 

ƒ

 

Inversion of the reading direction without recalibrating the system  

ƒ

 

Focus procedure to be performed only once during the first installation (even if the material being 
used changes, you do not have to repeat the procedure, simply perform the calibration) 

ƒ

 

No mechanical adjustment required for different materials being used (even if transparent or 
metallized) 

ƒ

 

Possibility of selecting the sensor response when there is no line/edge: 

1.

 

Storing the last value read: the belt guide searches for the line/edge even if it is outside of the 
sensor’s field of view. 

2.

 

Signal to the regulator that there is no line/edge: the regulator stops and waits for the 

line/edge to reappear inside the sensor’s field of view.    

 
 

 

Optional 

ƒ

 

Remote keyboard 

ƒ

 

Possibility to increase the degree of protection 

ƒ

 

Sensor cable with custom length  

ƒ

 

Analog output 0÷10Vdc 

 
 

 

Summary of Contents for TL01-A

Page 1: ...ENG TL01 A Optical sensor USER S MANUAL...

Page 2: ......

Page 3: ...2 TL01 A sensor functioning 3 Positioning the TL01 A sensor 4 Positioning the TL01 A sensor with contrast lamp 6 Quick start up 7 Electrical characteristics 10 Other characteristics 10 Optional 10 TL...

Page 4: ...pted in the member state in which it was installed WEEE Waste Electrical and Electronic Equipment may be intended for individual collective or mixed collection and recovery systems at designated centr...

Page 5: ...d changes Immediate display of the reading area with the Laser pointer Simple and quick calibration in just a few seconds Automatic selection of the illumination colour for maximum contrast the sensor...

Page 6: ...aptured contrast Field of view If the contrast is placed as shown in this diagram during the calibration the sensor will indicate the position of the first contrast dark light found by scan from left...

Page 7: ...upon request for 1 bars 25 4mm material The spacer useful to find the correct angle of the TL01 A in relation to the roller must be positioned between the sensor and the roller making sure that the ho...

Page 8: ...Re S p A TL01 A 03 07 12 5 13 In relation to the material angle the TL01 A sensor can be positioned as follows 70 5 7 0 5...

Page 9: ...Re S p A TL01 A 03 07 12 6 13 Positioning the TL01 A sensor with contrast lamp 70 5 64 8 37 5 45 50 29 5 8 7 20 61 50 80 20 transparent zone...

Page 10: ...an be used to perform the calibration Focus 1 2 The display will show a numerical value Move the sensor closer or further away from the material in order to achieve the maximum reflection value The va...

Page 11: ...ontemporaneously 2 the field of view expressed in mm will appear on the display as a number 3 press the right arrow to increase the field of view or press the left arrow to reduce it 4 once the desire...

Page 12: ...NTERRUPTED LINE FUNCTION You can activate the interrupted line function so that when the print is not present the belt guide does not perform any adjustment but it remains in stand by until the line a...

Page 13: ...L x P x H Response time 1msec Working temperature range 0 60 C Degree of protection IP40 Inversion of the reading direction without recalibrating the system Focus procedure to be performed only once...

Page 14: ...gnal White 12 24Vdc Black 0Vdc Blue 0 5Vdc analog output Brown LIN signal NC Pin connector Wires colour Signal 1 Blue 0 5Vdc analog output 2 Black 0Vdc 3 White 12 24Vdc 4 Brown LIN signal 1 2 3 4 L ma...

Page 15: ...dge Position the sensor or the material so that the line edge is inside the sensor s field of view The E M D function is not working the red LED is off The electronic movement is at the maximum NOTE i...

Page 16: ...guarantee includes spare parts and labour It does not include shipment costs for device delivery or recall The guarantee is invalidated by improper use of the device incorrect installation faulty elec...

Page 17: ...linea contrasto per messa a fuoco This page can be used to perform the focus procedure by using the black line printed as contrast to read...

Page 18: ......

Page 19: ...This page can be used to perform the focus procedure by using the black line printed as contrast to read...

Page 20: ...dustriali Via Firenze 3 20060 BUSSERO MI ITALY Fax 39 02 95 03 89 86 Technical support Tel 39 02 95 24 30 300 E mail support re spa com Sales support Tel 39 02 95 24 30 200 E mail sales re spa com www...

Reviews: