2.5 DIAGNOSTIC TABLE
ERROR CAUSE
LOGGED
DISPLAY
E01
No ‘NET SYNC’ signal. Replace on board fuse
Yes
Yes
E02
Temperature derivative insufficient
Only if P.82=1
Yes
E03
RS485 network error (future use)
Yes
Yes
E04
Tank temperature higher than T max (P.54)
Yes
Yes
E05 Tank
temperature
probe
CC or disconnected
Yes
Yes
E06
Recirculating temperature probe CC or disconnected
Only if P.51=1
Only if P.51=1
E07
SETUP data error
Yes
Yes
E08
SETUP data corrupted
Yes
Yes
E09
Tank temperature lower than T min (P.55)
Yes
Yes
E10
Triac control temperature probe CC or disconnected
Yes
Yes
EVENT DESCRIPTION
LOGGED
DISPLAY
d01 Legionella
cycle
start
Si
No
d02 Legionella
cycle
stop
Si
No
2.6 EVENT LIST
The event list is structured according to the following table:
The last 16 events (described in
2.5
) are registered.
“ SET” button allows to move horizontally,”UP” and “DOWN” buttons allow to move vertically. The first row of the
table contains the last recorded event.
2.7 SMART MANUAL OPERATIONS
Smart setup temperature (setpoint)
Press one time “UP” button; Display shows, for 1 sec, “P.01”, then the setpoint value (blinking). Press “UP” and
“DOWN” to set the desired.
Press “SET” button to confirm and return to main page.
Press “ON-OFF” to restore the old value and return to main.
Boost mode starting
By activating the BOOST mode, the heat pump and the electrical resistance (at the maximum set power) are
immediately activated to reach the desired temperature in the shortest possible time. When the temperature is
reached, the BOOST mode automatically switches off.
To activate the BOOST mode, from the On state (red LED off) press “UP” key for two seconds;display shows "Bst" for
two seconds, then the function is activated and the water temperature in the tank is displayed.