RDS Technology ICP 300 User Manual Download Page 4

ICP 300 IN-CAB PRINTER 

 

Setup 

 

Plug the printer cable RJ-12 connector into the back of the printer and then 
attach the mounting plate with the two M3 screws provided.  

The  cable  is  connected  normally  to  the  upper  port  on  a  ‘Pro-Series’/’Psi’ 
head unit, or into the ‘Terminator’ junction box of a ‘Wizard’ instrument (fig. 
2). 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 2  Connecting to a Wizard Head Unit 

 

Connect  the  lead  Pt  No.  S/CB/167-4-005  onto  the  4-way  connector  in  the 
terminal box as shown.   

Locate  the  cable  grommet  onto  the  moulding,  and  cable-tie  the  head  unit 
lead onto the moulded cable saddle to provide strain relief. 
 

 

 

 

RED WIRE 

Summary of Contents for ICP 300

Page 1: ...irective 2004 108 EC when installed and used in accordance with the relevant instructions Service and Technical Support PLEASE CONTACT YOUR NEAREST DISTRIBUTOR If unknown then fax 44 0 1453 733322 Cop...

Page 2: ...Operation ______________________________________________5 Power On Self Test _____________________________________5 Status LED _____________________________________________5 Replacing the paper roll_...

Page 3: ...oltage in the range 10 35V dc No maintenance is required except to occasionally clean the rubber paper roller to remove any dirt buildup Parts List Part No Description Qty S HU 167 4 001 ICP 300 Print...

Page 4: ...mally to the upper port on a Pro Series Psi head unit or into the Terminator junction box of a Wizard instrument fig 2 Figure 2 Connecting to a Wizard Head Unit Connect the lead Pt No S CB 167 4 005 o...

Page 5: ...on advances the paper Power On Self Test Press and hold the button and then power up the instrument The printer will then print a self test report The self test procedure checks most of the printer fu...

Page 6: ...lacing the paper roll Pull the lever up until the lid is released Do not use excessive force Figure 3 Unlock paper compartment Replace the roll and press the lid at each side until it clicks shut Figu...

Page 7: ...n be removed for cleaning if necessary Push the roller forwards at each end to disengage it from the slots figure 5 NOTE DO NOT angle the roller too far with one end still engaged as this may break th...

Page 8: ...C print ratio 25 Power Voltage External 10 35 V dc Operating Current From 1A 35V to 2 7A 10V Standby 30 mA Paper Paper roll 58mm x 44mm dia Paper specification TF50 KS E2D recommended I O Interface RS...

Page 9: ...ICP 300 IN CAB PRINTER 9 Issue 1 17 7 07 Original issue Issue 1 01 11 8 08 ref p 3 Parts List...