APOLLO FYM - SPREADER CONTROLLER
8
2.
Technician Config
The operator is unlikely to need access in normal use. Access to this menu can be restricted by changing the
PIN number from within the menu.
Enter the factory default PIN number 1234 to access the menu.
2.1
Display Options
2.1.1 Speed Smoothing Factor
The Forward Speed display is electronically damped. If the readouts are constantly changing by small
increments, you can increase the damping time to give a steadier readout.
Adjustable from 0 to 19 seconds.
Default = 2 seconds
2.1.2 Rate Lock-On
"RATE LOCK-ON" sets the % by which the application rate fluctuates either side of a nominal application rate
before the instrument display changes.
For example, if the actual application rate fluctuates in normal operation from 9.7 to 10.3 tonnes/ha for a target
application rate of 10 tonnes/ha, you may decide that it is acceptable for the instrument to display a steady
readout of 10 tonnes/ha between those limits i.e. ±3%. In this case the rate lock-on figure should be set to 3.0.
Adjustable from 0 to 50% Default = 2%
2.1.3 Rate Smoothing
The Application rate display is electronically damped. If the readouts are constantly changing by small
increments, you can increase the damping time to give a steadier readout.
Adjustable from 0 to 19 seconds.
Default = 2 seconds
2.1.4 Off Target Alarm
This sets the threshold at which the instrument will alarm "UNDER APPLICATION" or "OVER APPLICATION"
when Spreading in automatic control mode. It is set as a percentage either side of the current target rate.
Adjustable from 0 to 50%.
Default = 20%
2.1.5 Info Weight
Default = "
LOAD CELL
" - This means that the weight that is displayed on the INFO page as the job totals will
be taken from the load cell readings (as if using a weigh bridge) instead of the theoretical weight reading
based on the number of floor revolutions x calibration factor (
THEORY
)
2.
Technician Config.
1.
Display Options
UK572-12.PCX