EC9000i Series Scanner User Guide
Operating the scanner
Light signals and beeps
The scanner’s status is shown through a single, multistate LED (light-emitting diode), which is the light on
the top, front, right-hand side of the unit. The table below describes typical status signals and their
meanings.
During start up
Signals
Meaning / What to do
Red-red-green-green flashing
cycle
The scanner is being configured by the application. Wait for the
application to finish configuring the scanner.
Red-green flashing cycle
Red-amber-green
The scanner is connecting to the application. Wait for the scanner to
connect.
Green solid
The scanner is configured but idle. The scanner is ready.
During document scanning and processing
Signals
Meaning / What to do
Green flashing
The scanner is waiting for the user to insert a document into the
feeder.
Green flashing with one short
beep
The scanner read the document successfully.
Green-red flashing cycle
The scanner is processing the document. Wait for the scanner to
finish.
Red flashing and one short
beep
An error occurred while the scanner was processing the document.
Check your PC application for instructions or refer to your local
procedures. If you need more help, contact your distributor (reseller).
Red flashing and one long beep
An error occurred while the scanner was processing the document or
storing the captured image. Check your PC application for instructions
or refer to your local procedures. If you need more help, contact your
distributor (reseller).
Red flashing and three short
beeps
The scanner was not able to read the MICR line.
A typical document processing / LED cycle
1. The LED is Green (Solid): The unit is idle.
2. The LED is Green (Flashing): The scanner is waiting for a document to be inserted for scanning.
3. The LED is Green/Red (Flashing): The scanning operation is in progress.
4. The LED is Green (Solid): The scanning operation is complete. The scanner has returned to its
idle state.
©2014 RDM Corporation