![RCT 11966 Product Manual Download Page 10](http://html1.mh-extra.com/html/rct/11966/11966_product-manual_1424352010.webp)
10 | 12
M0879.docx
| Rev 1.6 | Modified on 11/01/2018 | © Remote Control Technologies Pty Ltd
12725 OVERCRANK CONTROLLER KIT (24 V)
PART NO.
DESCRIPTION
QUANTITY
INCLUDED PARTS
SUGGESTED SPARES
11966
Overcrank Controller
1
1
2401
24 V Relay
1
1
12738
Generic Loom
1
-
11112
Blue LED
1
-
12048
Warning LED Label
1
-
12049
Overcrank Bypass Label
1
-
3543
Key Switch Head Stay Put L/H
1
-
9476
Switch Body with 1 x N/O Contact
1
-
11981
LED Resistor
1
-
TECHNICAL SPECIFICATIONS
Dimensions, controller only
Length: 119 mm | Width: 80 mm | Height/Depth: 65 mm
Dimensions, boxed for freight
Length: 220 mm | Width: 120 mm | Height/Depth: 120 mm
Weight, controller only
255 g
Input nominal voltage
12 to 24 V DC
Min and max input voltage
9 to 35 V DC
Ignition output rated continuous
current
10 A
Connection types
12-pin receptacle
Inputs
Ignition supply, bypass input, battery supply, chassis ground
Circuit protection
External control
Enclosure type
ABS
Environmental protection IP rating
IP65
Programming/adjustment
Refer to
Calibration
section
COMPLIANCE AND STANDARDS
RCT has an obligation as a manufacturer to comply with the regulations as required by the relevant regulatory
bodies, depending on the market and location.
This product currently complies with the following:
ACMA
■
IEC 61000-6-1:2005 Electromagnetic Compatibility (EMC) – Part 6-1: Generic Standards – Immunity for
Residential, Commercial and Light Industrial Environments.
■
IEC 61000-6-3:2006, A1:2010 Electromagnetic Compatibility (EMC) – Part 6-3: Generic Standards –
Emissions for Residential, Commercial and Light Industrial Environments.
EU
■
IEC 61000-6-1:2005 Electromagnetic Compatibility (EMC) – Part 6-1: Generic Standards – Immunity for
Residential, Commercial and Light Industrial Environments.
■
IEC 61000-6-3:2006, A1:2010 Electromagnetic Compatibility (EMC) – Part 6-3: Generic Standards –
Emissions for Residential, Commercial and Light Industrial Environments.
■
RoHS 2 Directive 2011/65/EU
FCC
This device is exempt from FCC regulations under 47 CFR 15.103 Exempted devices.
IC
This device is exempt from IC regulations under ICES-003 — Information Technology Equipment (ITE) —
Limits and Methods of Measurement.