background image

 
R-FORCE FOR INNER DOORS – INSTALLING AND OPERATING 

INSTALLATION 

 

 

 

6.

 

Insert the lever shaft spring (

8

) and the lever shaft extender (

9

) into the lever (

7

) that is 

to be on the other side of the door. 

 

7.

 

Mount the lever (

7

) in the lock. 

8.

 

Mount R-FORCE (

11

) on the lever shaft extender and mount the other lever (

4

).  

9.

 

Gently tighten the retainer bolts (

10

). 

10.

 

Connect the red battery wire to one battery, the black wire to the other, and insert 
the batteries. 

Only use alkaline batteries of type 6LR61 (9V, 550 mAh).  

 

11.

 

Mount the two brass bolt extenders (

12

) on the cylinder ring (

13

). Mount the cylinder 

ring, cover plate (with the hole facing up if a modular lock is used) and lever. Align 
R-FORCE with the door surface and tighten the bolts.  

12.

 

Program R-FORCE as described below and check that it works correctly.  

Brass 

Summary of Contents for R-FORCE

Page 1: ...08 546 560 00 info rco se www rco se 2020 RCO Security AB All rights reserved November 2020 R FORCE for inner doors Installing and operating Describes how to mount program and troubleshoot the code l...

Page 2: ...g entry codes that unlock the door 10 Deleting codes 10 Activating or deactivating beep when opening 11 Adjusting how long the lock stays open 11 Activating or deactivating the battery warning sound 1...

Page 3: ...d The CE marking is on the back of each unit The marking is repeated on the inside of the unit s battery cover Environment The environmental declaration is available at www rco se Batteries Spent batt...

Page 4: ...d cylinder rings Otherwise everything that is needed for mounting is included in the box Batteries are not included Compatible door locks Some of the most common locks that R FORCE works with ASSA mod...

Page 5: ...he surface of the door must not be so uneven that R FORCE becomes deformed during mounting For security the gap between the door blade and the door frame should be as small as possible Change the defa...

Page 6: ...the two steel bolt extenders 1 and the washers 14 on the cylinder 2 Mount the cylinder and the cylinder extender 3 in the lock If the cylinder extender is too long the key will be difficult to turn In...

Page 7: ...r 4 9 Gently tighten the retainer bolts 10 10 Connect the red battery wire to one battery the black wire to the other and insert the batteries Only use alkaline batteries of type 6LR61 9V 550 mAh 11 M...

Page 8: ...inserted Programmed codes will not be lost What can happen is that the buzzer sounds constantly or that the codes do not work 1 Remove both batteries 2 Press six numbers in succession to reset the bat...

Page 9: ...at The following symbols are used in the instructions to show what the lamp is doing after each described step Off operating mode Steady shine programming mode Slow flashing menu selected Fast flashin...

Page 10: ...ry position Confirm with 4 Enter the desired code 3 6 digits Confirm with A beep confirms the change 5 To add more codes repeat steps 3 and 4 6 To exit menu 1 press 0 Select a new menu and press Or to...

Page 11: ...ction then 3 Press 1 submenu then 4 Press 1 to activate sound Or press 0 to deactivate it Confirm with A beep confirms the change 5 To exit press 0 then Adjusting how long the lock stays open You can...

Page 12: ...ote The system code cannot be the same as any of the access codes If the system code has more digits than a code but uses the same initial digits then subsequent digits must be entered within 2 second...

Page 13: ...itself will not open the door It s zero 0 that opens the door 1 Set the unit to programming mode by entering the system code 2 Press 3 menu selection then 3 Enter the desired code 3 6 digits Confirm...

Page 14: ...code 2 Press 9 menu selection then 3 Press 1 to confirm master reset Confirm again with A beep confirms the reset If the system code is not known If the system code has been lost the below procedure i...

Page 15: ...fy that R FORCE is correctly mounted parallel with the edge of the door and perpendicular to the door surface right angles to the lever shaft R FORCE should also be mounted with two screws 20 in the b...

Page 16: ...is working but beeps three times when an access code is entered This is the battery warning Change the batteries See Changing the batteries on page 8 The buzzer sounds constantly or no codes are worki...

Page 17: ...s code entered Steady shine Programming mode Or valid access code entered door unlocked Slow flashing A menu was selected waiting for you to select a submenu or enter a new value for example a memory...

Page 18: ...5 V Current consumption Idle 14 18 mA Programming mode 1000 mA Activation pulse 559 mA Deactivation pulse 380 mA Battery life of fresh batteries 100 accesses 24h 34 months 50 accesses 24h 40 months S...

Page 19: ...CE FOR INNER DOORS INSTALLING AND OPERATING CONFIGURED CODES 19 Configured codes Code position Description Code 1 2 3 4 5 6 7 8 9 Code for activating and deactivating access code 0 see page 13 System...