Wire Gauge Chart courtesy of Electronic Locking Devices by John L. Schum

8371/ 8372 Electromagnetic Lock Installation Instructions 

(Continued)

WIRE GAUGE SELECTIONS

6

Total One-Way 

Length of Wire 

Run (ft.)

Load Current @ 24V

1/4A

1/2A

3/4A

1A

1-1/4A

1-1/2A

2A

3A

100

24

20

18

18

16

16

14

12

150

22

18

16

16

14

14

12

10

200

20

18

16

14

14

12

12

10

250

18

16

14

14

12

12

12

10

300

18

16

14

12

12

12

10

-

400

18

14

12

12

10

10

-

-

500

16

14

12

10

10

-

-

-

750

14

12

10

10

-

-

-

-

1000

14

10

10

-

-

-

-

-

1500

12

10

-

-

-

-

-

-

Total One-Way 

Length of Wire 

Run (ft.)

Load Current @ 12V

1/4A

1/2A

3/4A

1A

1-1/4A

1-1/2A

2A

3A

100

20

18

16

14

14

12

12

10

150

18

16

14

12

12

12

10

-

200

16

14

12

12

10

10

-

-

250

16

14

12

10

10

10

-

-

300

16

12

12

10

10

-

-

-

400

14

12

10

-

-

-

-

-

500

14

10

10

-

-

-

-

-

750

12

10

-

-

-

-

-

-

1000

10

-

-

-

-

-

-

-

1500

10

-

-

-

-

-

-

-

Summary of Contents for 8371

Page 1: ...t must be installed according to all applicable building and life safety codes 2 Due to the variety of mounting configurations available with this product a survey and assessment of the physical area in which the product will be installed must be performed 3 The door frame must be inspected and deemed structurally sound prior to installation of the electromagnetic lock The structural integrity of ...

Page 2: ...he desired manner Magnet power from Power Supply 12 24VDC input Ground Jumper 12VDC Jumper 24VDC preset Power Input Requirements MODEL 12VDC 24VDC 8371 0 52A 0 26A 8372 1 04A 0 52A 2 x BLUE LEADS Normally Open FOR MODELS WITH OPTIONAL DSS contacts are rated 0 20A 12VDC and 0 12A 24VDC shown with Door Open Wiring For Unmonitored or DSS Sensor Models 12 24 12 G B R LED R B G HR VDC C NC NO G B R LED...

Page 3: ...unting bracket 8371 Lock Dimensions 1 D x 1 7 8 W x 9 3 8 L 25 x 48 x 238mm 8372 Lock Dimensions 1 D x 1 7 8 W x 18 3 4 L 25x 48 x 476mm Armature Plate Dimensions 1 2 D x 1 1 2 W x 7 1 4 L 13 x 38 x 185mm Electrical Voltage 12VDC or 24VDC Current Max 0 52A at 12VDC each lock on 8372 model Max 0 26A at 24VDC each lock on 8372 model SCS Output Relay SPDT relay Contacts rated at 1 0A 24VDC DSS Reed S...

Page 4: ... 4 thick glass doors Used to provide extra mounting space in a hollow metal or wood frame where the door stop of the frame is not thick enough to allow a lock to be installed Available in several different heights and widths For use when an obstruction in the door prevents the installation of the armature plate at a proper height If the armature plate needs to be lowered then a spacer bar can be u...

Page 5: ...two separate categories for use in both the United States and Canada Auxiliary Lock The GWXT fire listing qualifies these for use with UL Classified fire doors maximum 4 in width and 8 in height The 8371 and 8320 are rated up to and including 1 hr Special Locking Arrangement Component Additionally these products are qualified components for the purpose of locking outward swinging exit doors agains...

Page 6: ... Wire Run ft Load Current 24V 1 4A 1 2A 3 4A 1A 1 1 4A 1 1 2A 2A 3A 100 24 20 18 18 16 16 14 12 150 22 18 16 16 14 14 12 10 200 20 18 16 14 14 12 12 10 250 18 16 14 14 12 12 12 10 300 18 16 14 12 12 12 10 400 18 14 12 12 10 10 500 16 14 12 10 10 750 14 12 10 10 1000 14 10 10 1500 12 10 Total One Way Length of Wire Run ft Load Current 12V 1 4A 1 2A 3 4A 1A 1 1 4A 1 1 2A 2A 3A 100 20 18 16 14 14 12 ...