RCI 8371 Installation Manual Download Page 4

Product Accessories Guide

Top Jamb bracket and angle bracket kit is required for use when 

mounting the lock on a door that swings inwards. Magnet mounts to 

the underside of an angle bracket mounted on the frame. Armature 

plate mounts to “Z” bracket assembly mounted to door face.

  

Used in a narrow head jamb situation or for center-hung doors. 

Any place where there is insufficient frame depth to mount the lock.

Available in several different sizes and finishes. 

  

Allows an armature plate to be mounted to a glass or Herculite door 

that does not have a frame. The Glass Door Bracket is a “U”-shaped 

piece of 1/16” thick material that slips over the top of the glass 

panel and tightens to the glass with setscrews. The Armature plate 

mounts directly to the surface of the bracket by means of a threaded 

hole in the bracket assembly plate.

Available for both 1/2” and 3/4” thick glass doors.

Used to provide extra mounting space in a hollow metal or wood 

frame where the door stop of the frame is not thick enough to allow 

a lock to be installed.

Available in several different heights and widths.

For use when an obstruction in the door prevents the installation of 

the armature plate at a proper height. If the armature plate needs 

to be lowered then a spacer bar can be used to lower the lock from 

the frame.

Available in several different heights.

  

For use with doors that do not permit the armature plate to be 

mounted low enough to meet the magnet surface. Eg: Some 

aluminum framed commercial glass doors. The armature holder can 

be mounted to whatever frame is available and the armature plate in 

turn mounted to the holder.

Available in pocket style. 

 

Top Jamb Bracket  

Angle Bracket 

Glass Door Bracket

 Filler  Bars

Spacer Bars

Armature Holder

            Part   

 

 

 

Usage   

 

 

                  Example

8371/ 8372 Electromagnetic Lock Installation Instructions 

(Continued)

4

Accessories may impact holding force. 

(Separate installation instructions provided with accessories.)

Summary of Contents for 8371

Page 1: ...t must be installed according to all applicable building and life safety codes 2 Due to the variety of mounting configurations available with this product a survey and assessment of the physical area in which the product will be installed must be performed 3 The door frame must be inspected and deemed structurally sound prior to installation of the electromagnetic lock The structural integrity of ...

Page 2: ...he desired manner Magnet power from Power Supply 12 24VDC input Ground Jumper 12VDC Jumper 24VDC preset Power Input Requirements MODEL 12VDC 24VDC 8371 0 52A 0 26A 8372 1 04A 0 52A 2 x BLUE LEADS Normally Open FOR MODELS WITH OPTIONAL DSS contacts are rated 0 20A 12VDC and 0 12A 24VDC shown with Door Open Wiring For Unmonitored or DSS Sensor Models 12 24 12 G B R LED R B G HR VDC C NC NO G B R LED...

Page 3: ...unting bracket 8371 Lock Dimensions 1 D x 1 7 8 W x 9 3 8 L 25 x 48 x 238mm 8372 Lock Dimensions 1 D x 1 7 8 W x 18 3 4 L 25x 48 x 476mm Armature Plate Dimensions 1 2 D x 1 1 2 W x 7 1 4 L 13 x 38 x 185mm Electrical Voltage 12VDC or 24VDC Current Max 0 52A at 12VDC each lock on 8372 model Max 0 26A at 24VDC each lock on 8372 model SCS Output Relay SPDT relay Contacts rated at 1 0A 24VDC DSS Reed S...

Page 4: ... 4 thick glass doors Used to provide extra mounting space in a hollow metal or wood frame where the door stop of the frame is not thick enough to allow a lock to be installed Available in several different heights and widths For use when an obstruction in the door prevents the installation of the armature plate at a proper height If the armature plate needs to be lowered then a spacer bar can be u...

Page 5: ...two separate categories for use in both the United States and Canada Auxiliary Lock The GWXT fire listing qualifies these for use with UL Classified fire doors maximum 4 in width and 8 in height The 8371 and 8320 are rated up to and including 1 hr Special Locking Arrangement Component Additionally these products are qualified components for the purpose of locking outward swinging exit doors agains...

Page 6: ... Wire Run ft Load Current 24V 1 4A 1 2A 3 4A 1A 1 1 4A 1 1 2A 2A 3A 100 24 20 18 18 16 16 14 12 150 22 18 16 16 14 14 12 10 200 20 18 16 14 14 12 12 10 250 18 16 14 14 12 12 12 10 300 18 16 14 12 12 12 10 400 18 14 12 12 10 10 500 16 14 12 10 10 750 14 12 10 10 1000 14 10 10 1500 12 10 Total One Way Length of Wire Run ft Load Current 12V 1 4A 1 2A 3 4A 1A 1 1 4A 1 1 2A 2A 3A 100 20 18 16 14 14 12 ...