Specifications

MECHANICAL

 

(Including 1/4” [6.4mm] mounting bracket):

8310 lock Dimensions: 

1-5/8”D x 2-7/8”W x 10-1/2”l (41mm x 73mm x 268mm)

8320 lock Dimensions: 

1-5/8”D x 2-7/8”W x 21-1/8”l (41mm x 73mm x 536mm)

Standard Armature plate dimensions: 

5/8”D x 2-3/8”W x 7-7/16”l (16mm x 61mm x 190mm)

DSS Armature plate is 10”l (252mm) 

ELECTRICAL:
Voltage:
 auto-sensing 12vDC to 24vDC 
Current:  0.23A @ 12vDC

 

0.13A @ 24vDC

 

NoTe: 8320 lock contains 2 control boards  

 that  will  each draw these Amps.

SCS Output Relay*: SPDT relay. Contacts rated at 2A@24vDC
DSS Reed Switch*: Magnetically actuated SPDT switch. 

Contacts rated for 0.20A @12vDC and 0.12A @ 24vDC

*

 effective for either resistive or inductive loads 

 (power  factor 

 0.6 with inductive loads)

ENVIRONMENTAL: Not for use in outdoor environments.
Circuit board operating temperature: 32˚ to 120˚F (0˚ to 49˚C)

NOTE: Specifications may change without notice.

8300 Series Troubleshooting Guide

8310 & 8320 Electromagnetic Lock

Installation Instructions 

(Continued)

4

Problem

Solution

Cannot remove the lock mounting bracket from top of magnet for 

installation.

Remove anti-tamper screw and cavity screw. Insert supplied Allen wrench into 

mounting bolt holes in the bottom of the lock housing and turn. (See Fig.3)

lock is installed but has no holding force at all.

Check power supply. DC power should be slightly over the voltage

specifications outlined on the packaging. eg: for 12vDC operation

supply should be set at 12vDC-13vDC.

Check connections at power supply, connected releasing devices, lock

terminals and lock circuit board to magnet core.

Check delayed relock wiring and time setting.

Check that the momentary switch does not include a shunted light option.

lock has enough holding force to lightly hold a screwdriver or set

of pliers but door will not lock.

Check to see that armature plate is correctly aligned with the 

electromagnetic lock. If there is improper alignment, make a 1/4 turn of the 

armature plate mounting bolt and check for alignment.  

Make sure to follow the armature plate mounting instructions on the 

template and Page 1 of this install.

lock is operating and locking but the armature plate is “humming”

against the surface of the lock.

This generally indicates that the lock is either operating on AC voltage or there 

is some AC voltage present in the DC supply. A properly filtered and regulated 

DC power supply is required to achieve optimal operation from the lock.

lock is not releasing immediately upon removal of powe

r

ensure that switching devices are interrupting the DC power and not the 

AC power supply voltage. 

ensure rubber washer on armature plate mounting bolt has not been 

removed or damaged.

Check that switching device interrupts the positive wire and not the  

negative wire (See Fig. 2)

Remove any Diodes or other suppression devices that may be installed.

Voltage

8310

8320

12vDC

0.23A

0.23A x 2= 0.46A

24vDC

0.13A

0.13A x 2= 0.26A

Power Supply

NOTE: All RCI electromagnetic locks must be powered with filtered and regulated DC power supplies such as the RCI 10 Series ul 

listed power supply. RCI offers a full line of power supplies and switching devices that are suitable for use with the 8300 Series locks.

Summary of Contents for 8310

Page 1: ...rations available with this product a survey and assessment of the physical area in which the product will be installed must be performed 3 The door frame must be inspected and deemed structurally sound prior to installation of the electromagnetic lock The structural integrity of the mounting surfaces must be strong enough to meet or exceed the holding force of the product 4 The product must be pr...

Page 2: ...inal of the lock in Fig 2 Switching the negative power supply line will not allow the lock to release immediately RCI electromagnetic locks contain MOV s for surge suppression and do not require any additional suppression to be added during installation The installation of diodes across the lock input terminals will cause a delay in release Fig 2 Power Connections SWITCH INCORRECT CORRECT SWITCH F...

Page 3: ... at the bolt There should be no movement to the mounting bracket or housing of the electromagnetic lock For added safety thread locking compound has been provided for the armature plate bolt and the four captive electromagnetic lock mounting screws WARNING Improper installation maintenance inspection or usage of the product or any related accessories or parts may cause the electromagnetic lock arm...

Page 4: ...cted releasing devices lock terminals and lock circuit board to magnet core Check delayed relock wiring and time setting Check that the momentary switch does not include a shunted light option Lock has enough holding force to lightly hold a screwdriver or set of pliers but door will not lock Check to see that armature plate is correctly aligned with the electromagnetic lock If there is improper al...

Page 5: ...ere there is insufficient frame depth to mount the lock Available in several different sizes and finishes L Bracket Required wherever there is insufficient space on the frame header to mount the lock The lock mounts to the underside of the L bracket and the L bracket then gets mounted to the doorframe Available in several finishes Glass Door Bracket Allows an armature plate to be mounted to a glas...

Page 6: ...ide extra mounting space in a hollow metal or wood frame where the door stop of the frame is not thick enough to allow a lock to be installed Available in several different heights and widths Spacer Bars For use when an obstruction in the door prevents the installation of the armature plate at a proper height If the armature plate needs to be lowered then a spacer bar can be used to lower the lock...

Page 7: ...10 1000 14 10 10 1500 12 10 Total One Way Length of 1 4A 1 2A 3 4A 1A 1 1 4A 1 1 2A 2A 3A Wire Run ft 100 20 18 16 14 14 12 12 10 150 18 16 14 12 12 12 10 200 16 14 12 12 10 10 250 16 14 12 10 10 10 300 16 12 12 10 10 400 14 12 10 500 14 10 10 750 12 10 1000 10 1500 10 Load Current 24V Load Current 12V Wire Gauge Chart courtesy of Electronic Locking Devices by John L Schum WIRE GAUGE SELECTIONS 7 ...

Page 8: ...CATION DATE NOTES INITIAL 8310 8320 Electromagnetic Lock Installation Instructions Continued 2017 Rutherford Controls Int l dormakaba Group www rutherfordcontrols com Phone 1 800 265 6630 Fax 1 800 482 9795 E mail sales rutherfordcontrols com ...

Reviews: