RCF TT1-A Owner'S Manual Download Page 7

7

ENGLISH

REAR

PANEL

 

FEMALE XLR INPUTS (BAL/UNBAL). The system accept XLR input connectors.

 

MALE  XLR  SIGNAL  OUTPUT.  The  output  XLR  connector  provides  a  loop  through  for 

speakers daisy chaining. The balanced connector is connected in parallel and can be used to 
send the audio signal to other amplified speakers, recorders or supplementary amplifiers.

 

SYSTEM SET UP ENCODER. Push the encoder to select a function (gain reduction, delay, 

preset). Rotate the encoder to select a value or a preset.

 

GAIN REDUCTION LED. Pushing the encoder once the gain reduction indicator lights green. 

Then rotate the encoder to reduce the gain to the right level.

 

DELAY LED. Pushing the encoder twice the delay indicator lights green. Then rotate the 

encoder to delay the speaker. The delay is expressed in meters.

 

PRESET LED. Pushing the encoder three times the preset indicator lights green. Then rotate 

the encoder to load the right preset to the speaker.

 

SYSTEM  SET  UP  DISPLAY.  Display  the  system  setting  values.  In  case  of  RDNet  active 

connection a rotating segment will light up.

 

RDNET LOCAL SETUP/BYPASS. When released the local setup is loaded and RDNet can 

only monitor the speaker. When switched the RDNet setup is loaded and bypass any speaker 
local preset.

 

RDNET RECALL LED. This orange LED lights up when the LOCAL SETUP/BYPASS switch is 

pressed. If connected, RDNet is taking control of the speaker the speaker.

 

AC RDNET IN/OUT PLUG OPTION. The AC RDNET IN/OUT PLUG optional accessory can 

be installed removing a blind panel on the right side of the board. In the picture the installed 
accessory is shown.

 

LIMITER LED. The amplifier has a built in limiter circuit to prevent clipping of the amplifiers 

or overdriving the transducers. When the soft clipping circuit is active the LED blinks RED. It is 
okay if the limit LED blinks occasionally. If the LED lights continuously, turn down the signal 
level.

1

2

3

4

5

6

7

8

9

10

11

1

2

11

10

9

8

7

12

13

14

3

6

4

5

Summary of Contents for TT1-A

Page 1: ...OWNER MANUAL TT1 A TT2 A TT5 A HIGH OUTPUT ACTIVE SPEAKERS ...

Page 2: ......

Page 3: ...3 ENGLISH ENGLISH ITALIANO LANGUAGE 4 11 ...

Page 4: ...cur the product does not function or functions in an anomalous way The power cable has been damaged Objects or liquids have got in the unit The product has been subject to a heavy impact 5 If this product is not used for a long period disconnect the power cable 6 If this product begins emitting any strange odours or smoke switch it off immediately and disconnect the power cable 7 Do not connect th...

Page 5: ...NT NOTES To prevent the occurrence of noise on line signal cables use screened cables only and avoid putting them close to Equipment that produces high intensity electromagnetic fields Power cables Loudspeaker lines OPERATING PRECAUTIONS Place this product far from any heat sources and always ensure an adequate air circulation around it Do not overload this product for a long time Never force the ...

Page 6: ... processes allows us to seamlessly integrate all the ingredients to design and buildTT The design philosophy for the newTT series is based upon offering the sound engineer solutions and tools that are ready to use Key factors are the ability to sustain very high power with highly efficient sound pressure levels Intense sound levels are created with extremely high definition and extendeddynamicrang...

Page 7: ...n rotate the encoder to load the right preset to the speaker SYSTEM SET UP DISPLAY Display the system setting values In case of RDNet active connection a rotating segment will light up RDNET LOCAL SETUP BYPASS When released the local setup is loaded and RDNet can only monitor the speaker When switched the RDNet setup is loaded and bypass any speaker local preset RDNET RECALL LED This orange LED li...

Page 8: ...ion LED will light up Now rotating the encoder counter clockwise it will be possible to reduce the input gain The gain reduction will be in steps of 0 1 dB for the first 10 dB and than in 1 dB steps The maximum reduction is 99 dB Pushing a second time the rear encoder the delay LED will light up Now rotating the encoder clockwise it will be possible to delay the signal output of the speaker The de...

Page 9: ...24 dB oct high pass filter at 100 Hz F1 FAR Far listening preset To be used when the average listener distance is more than 10 meter The preset shows a 3 dB shelf in high frequencies to compensate the air absorption The clarity and intelligibility in distance are improved F2 FAR HIGH PASS This preset is the same as F1 with a 24 dB oct high pass filter at 100 Hz After the parameter settings the 2 d...

Page 10: ...after the show Now you can turn ON the speaker and adjust the volume control to a proper level BEFORE TURNING ON THE SPEAKER WARNING daisy chaining speakers always make sure that the maximum current requirement does not exceed the maximum admitted POWERCON current In case of doubt call the closest RCF SERVICE CENTRE INSTALLATION WARNING The fuse settings replacement shall be as follow TT1 A 230 Vo...

Page 11: ...dotto interventi modifiche riparazioni se non quelle espressamente descritte sul manuale istruzioni Contattare centri di assistenza autorizzati o personale altamente qualificato quando l apparecchio non funziona o funziona in modo anomalo Il cavo di alimentazione è danneggiato Oggetti o liquidi sono entrati nell apparecchio L apparecchio ha subito forti urti 5 Qualora questo prodotto non sia utili...

Page 12: ...e che i monitor da studio sono in grado di produrre NOTE IMPORTANTI Per evitare fenomeni di rumorosità indotta sui cavi che trasportano segnali dai microfoni o di linea per esempio 0 dB usare solo cavi schermati ed evitare di posarli nelle vicinanze di apparecchiature che producono campi elettromagnetici di forte intensità cavi di rete linee che alimentano altoparlanti PRECAUZIONI D USO Collocare ...

Page 13: ...cniche e strumenti acustici di immediato utilizzo Fattori chiave sono la capacità di sostenere elevati livelli di potenza e di pressione sonora con grande efficienza Intensi livelli sonori sono riprodotti con una definizione estremamente elevata ed estesa dinamica I materiali high tech con i quali è costruita la serie TT permettono di ottenere un peso complessivo molto basso facilitando quindi sos...

Page 14: ...enti di set up del sistema Nel caso in cui sia attiva una connessione RDNet il display mostrerà un segmento rotante TASTO RDNET LOCAL SETUP BYPASS Quando il tasto è rilasciato viene caricato il set up locale ed RDNet può solo monitorare il diffusore Quando il tasto è premuto RDNet ha il controllo del diffusore il preset locale è bypassato e viene caricato il preset impostato tramite RDNet LED RDNE...

Page 15: ...otando l encoder in senso antiorario è possibile ridurre il guadagno in ingresso La riduzione del guadagno avviene in passi da 0 1 dB per i primi 10 decibel ed in passi da 1 dB per i successivi La riduzione massima del guadagno in ingresso è di 99 dB Premendo una seconda volta l encoder posteriore si illumina il LED dell impostazione del ritardo temporale del diffusore Ora ruotando l encoder in se...

Page 16: ...ct a 100 Hz F1 FAR Preset per ascolto distante Questo preset è utile in caso di ascolto a distanze superiori a 11 metri Il preset mostra una leggera enfasi 3 dB shelf alle alte frequenze per compensare l assorbimento dell aria Utilissimo per aumentare la chiarezza e l intelligibilità in distanza F2 FAR HIGH PASS Questo preset è simile al F1 ma con un filtro passa alto a 24 dB oct a 100 Hz Dopo l i...

Page 17: ... è buona regola che i diffusori amplificati e gli amplificatori in genere siano sempre le ultime apparecchiature ad essere accese dopo il montaggio e le prime ad essere spente alla fine dello spettacolo A questo punto potete accendere il diffusore e alzare il controllo di livello a seconda delle necessità PRIMA DI ACCENDERE IL DIFFUSORE INSTALLAZIONE ATTENZIONE ATTENZIONE quando più diffusori veng...

Page 18: ...tt 500 Watt 735 x 443 x 529 42 0 Kg TT5 A XLR male female Powercon male female Gain reduction RDNet local setup bypass Time delay Presets Linear Close Far listening High pass RDNet ready 2 way equalisation crossover fast limiter RMS limiter Dynamic processing SPECIFICATIONS µ ACOUSTICAL Operating frequency range Max SPL Coverage Crossover point TRANSDUCERS Low frequency High frequency AMPLIFIER To...

Page 19: ......

Page 20: ...39 0522 274 411 e mail info rcf it RCF UK e mail info rcfaudio co uk RCF France e mail france rcf it RCF Germany e mail germany rcf it RCF Spain e mail info rcfaudio es RCF Belgium e mail belgium rcf it RCF USA Inc e mail info rcf usa com www rcf it ...

Reviews: