Pushing the rear encoder, it is possible to select the following three functions: - input gain 
reduction - speaker delay setting - selection of a speaker preset 

Pushing once the rear encoder the gain reduction LED will light up. Now rotating the 
encoder counter clockwise, it will be possible to reduce the input gain. The gain reduction 
will be in steps of 0,1 dB for the first 10 dB and then in 1 dB steps. The maximum reduction 
is 99 dB. 

Pushing a second time the rear encoder the delay LED will light up. Now rotating the 
encoder clockwise it will be possible to delay the signal output of the speaker. The delay is 
expressed in meter. The delay will be in steps of 0,1 m for the first 10 m and then in 1 m 
steps. The maximum delay will be 20 meter.
Pushing a third time the rear encoder the preset LED will light up. Now rotating the encoder 
clockwise it will be possible to select a preset:

EXTENDED LOW PRESETS

 (more extended and linear frequency response):

L1 

30 Hz – 60 Hz

L2 

30 Hz – 80 Hz

L3 

30 Hz – 100 Hz

L4 

30 Hz – 125 Hz

HARD PRESETS

 (less extended frequency response, more pressure at 50-60 Hz):

H1 

40 Hz – 60 Hz

H2 

40 Hz – 80 Hz

H3 

40 Hz – 100 Hz

H4 

40 Hz – 125 Hz

CARDIOID PRESETS

 (in combination with L presets)

C1 

30 Hz – 60 Hz

C2 

30 Hz – 80 Hz

C3 

30 Hz – 100 Hz

C4 

30 Hz – 125 Hz

After the parameter settings the two digits display will flash one time. This represent 
saving all the preset values in the speaker memory. Once saved, all the speaker settings are 
permanent. It is possible to turn off and turn on; the speaker will remember the last settings.

THE REAR ENCODER 

AND SUBWOOFER

SET-UP

SAVING A SPEAKER PRESET

 

AC POWERCON RECEPTACLE. RCF SUB series uses a POWERCON locking 3-pole AC 

mains. Always use the specific power cord provided in the package.

 

AC OUTPUT. Powercon locking 3-pole AC mains output.

9

10

9

10

Summary of Contents for SUB 8003-AS II

Page 1: ...OWNER MANUAL SUB 8003 AS II SUB 905 AS II ACTIVE SUBWOOFERS...

Page 2: ...2 ENGLISH ENGLISH ITALIANO LANGUAGE 4 10...

Page 3: ...ur the product does not function or functions in an anomalous way The power cable has been damaged Objects or liquids have got in the unit The product has been subject to a heavy impact 5 If this prod...

Page 4: ...T NOTES To prevent the occurrence of noise on line signal cables use screened cables only and avoid putting them close to Equipment that produces high intensity electromagnetic fields Power cables Lou...

Page 5: ...ransportation but also assist in the heat dissipation The new loudspeaker design looks aggressive whilst retaining perfect ergonomics and is the result of extensive combined functional and acoustic re...

Page 6: ...There are two possible high pass choices 30 Hz or 40 Hz and four low pass choices 60 Hz 80 Hz 100 Hz 125 Hz for eight preset combinations Cardioid presets are available for all 30 Hz high pass preset...

Page 7: ...t LED will light up Now rotating the encoder clockwise it will be possible to select a preset EXTENDED LOW PRESETS more extended and linear frequency response L1 30 Hz 60 Hz L2 30 Hz 80 Hz L3 30 Hz 10...

Page 8: ...reset The 2 front modules shall have 1 5 dB gain less than the rear module HOT GND BAL XLR COLD CONNECTIONS CARDIOID SET UP The fuse settings replacement shall be as follow FUSE VALUE T 6 30 A H 250 V...

Page 9: ...prodotto interventi modifiche riparazioni se non quelle espressamente descritte sul manuale istruzioni Contattare centri di assistenza autorizzati o personale altamente qualificato quando l apparecch...

Page 10: ...re che i monitor da studio sono in grado di produrre NOTE IMPORTANTI Per evitare fenomeni di rumorosit indotta sui cavi che trasportano segnali dai microfoni o di linea per esempio 0 dB usare solo cav...

Page 11: ...durante il trasporto e gli urti ma assiste la dissipazione termica Il nuovo design della Sub Series risulta aggressivo pur mantenendo caratteristiche ergonomiche familiari ed il risultato di estese r...

Page 12: ...ssibili due scelte di passa alto 30 Hz e 40 Hz e quattro scelte di passa basso 60 Hz 80 Hz 100 Hz 125 Hz Sono inoltre disponibili preset per configurazione cardioide nel caso di passa alto configurato...

Page 13: ...ore Il ritardo espresso in metri Il ritardo in passi da 0 1 metri per i primi 10 metri e in passi da un metro per i successivi Il massimo ritardo di 20 metri Premendo una terza volta l encoder posteri...

Page 14: ...nte sar un mixer importante anche che il mixer sia gi acceso al momento in cui viene acceso il diffusore a lui collegato Queste due precauzioni vi eviteranno innanzitutto di accendere i diffusori in p...

Page 15: ...35 dB 18 4 0 v c Stereo XLR Stereo XLR 0 dBu 99 dBu Selectable thermal rms dynamic limiter Gain EQ xover delay cardioid 2200 W Peak 2200 W Peak convection Powercon in out 694 mm 27 32 523 mm 20 59 700...

Page 16: ...www rcf it RCF S p A Via Raffaello Sanzio 13 42124 Reggio Emilia Italy Tel 39 0522 274 411 Fax 39 0522 232 428 e mail info rcf it 10307484 RevA...

Reviews: