13
P SERIES
5.5 System parameters array P 2110
* 96 dB SPL 400Hz-4 kHz with no atmospheric effects; rounded to the nearest 1 meter
NOTE: The distances indicated in the table are referred to the frequency range 400Hz-4 kHz.
Array
system
Inclination
angle (
α
)
Distance MAX
*
Coverage Angle - 6 dB
(H - V)
Accessory to
be used
Suggested
Amplifier
400 Hz - 4 Khz
500 Hz
1 kHz
2 kHz
4 kHz
23 - A
53 - B
0 °
0 °
25 m
170°x70°
90°x35°
110°x20°
80°x50°
AC P15A-BR
HPS 1500
24 - A
24 - B
0 °
30 °
20 m
170°x80°
90°x40°
110°x30°
80°x80°
AC P15A-BR
HPS 1500
25 - A
25 - B
25 - C
0 °
10 °
10 °
25 m
170°x50°
90°x30°
110°x80°
80°x60°
2 X
AC P15A-BR
HPS 1500
26 - A
26 - B
26 - C
0 °
0 °
30 °
30 m
170°x55°
90°x40°
110°x90°
80°x80°
2 X
AC P15A-BR
HPS 1500
27 - A
27 - B
27 - C
27 - D
0 °
0 °
0 °
0 °
35 m
170°x40°
90°x20°
110°x20°
80°x50°
2 X
AC P15A-BR
HPS 1500
28 - A
28 - B
28 - C
28 - D
0 °
0 °
10 °
30 °
25 m
170°x45°
90°x50°
110°x50°
80°x80°
2 X
AC P15A-BR
HPS 1500
29 - A
29 - B
29 - C
29 - D
0 °
10 °
10 °
10 °
30 m
170°x40°
90°x40°
110°x90°
80°x70°
2 X
AC P15A-BR
HPS 1500
30 - A
30 - B
30 - C
30 - D
0 °
20 °
20 °
30 °
20 m
170°x80°
90°x90°
110°x130°
80°x115°
2 X
AC P15A-BR
HPS 1500