background image

4

ENGLISH

IMPORTANT NOTES

WARNING

SAFETY AND OPERATING 

PRECAUTIONS

Before connecting and using this product, please read this user manual carefully and keep 
it on hand for future reference. This manual is to be considered an integral part of this 
product and must accompany it when it changes ownership as a reference for correct 
installation and use as well as for the safety precautions.
RCF S.p.A. will not assume any responsibility for the incorrect installation and / or use of 
this product.

SAFETY AND OPERATING PRECAUTIONS
1. 

All the precautions, in particular the safety ones, must be read with special attention, as 

they provide important information.

2.

 Speaker lines (amplifier outputs) can have a sufficiently high voltage (i.e. 100-70 V) to 

involve a risk of electrocution: never install or connect speakers when the line is alive.

3.

 Make sure all connections have been made correctly and the input voltage of every 

speaker is suitable for the amplifier output.

4. 

Protect speaker lines from damage. Make sure they are positioned in a way that they 

cannot be stepped on or crushed by objects.

5. 

Make sure that no objects or liquids can get inside speakers, as this may cause a short 

circuit.

6. 

Never attempt to carry out any operations, modifications or repairs that are not expressly 

described in this manual.

Contact your authorized service centre or qualified personnel should any of the following 

occur:

 

-

A speaker does not function (or works in an anomalous way).

 

-

A cable has been damaged.

 

-

Objects or liquids have got inside a speaker.

 

-

A speaker has been damaged due to heavy impacts or fire.

7.

 Should a speaker emit any strange smell or smoke, remove it from the line after having 

immediately switched the amplifier off.

8.

 Do not connect speakers to any equipment or accessories not foreseen.

For suspended installation, only use the dedicated anchoring points and do not try to hang 

speakers by using elements that are unsuitable or not specific for this purpose.

Also check the suitability of the support surface to which the product is anchored (wall, 

ceiling, structure, etc.) and the components used for attachment (wall plugs, screws, 

brackets not supplied by RCF, etc.), which must guarantee the security of the system / 

installation over time, also considering, for example, the mechanical vibrations normally 

generated by transducers.

9. RCF S.p.A.

 strongly recommends that speakers are only installed by professional 

qualified installers (or specialised firms) who can ensure a correct installation and certify it 

according to the regulations in force.

The entire audio system must comply with the current standards and regulations regarding 

electrical systems.

10.

 Mechanical and electrical factors need to be considered when installing professional 

audio systems (in addition to those which are strictly acoustic, such as sound pressure, 

angles of coverage, frequency response, etc.).

Summary of Contents for MR 40T

Page 1: ...USER MANUAL MANUALE D USO MR 40T MR 40T W MR 50T MR 50T W COMPACT MONITORS WITH CONSTANT DIRECTIVITY MONITOR COMPATTI A DIRETTIVITÀ COSTANTE ...

Page 2: ......

Page 3: ...AND OPERATING PRECAUTIONS DESCRIPTION CONNECTION INSTALLATION SPECIFICATIONS ITALIANO AVVERTENZE PER LA SICUREZZA DESCRIZIONE COLLEGAMENTO INSTALLAZIONE DATI TECNICI 4 6 6 10 11 14 16 16 20 21 TABLE OF CONTENTS INDICE ...

Page 4: ... service centre or qualified personnel should any of the following occur A speaker does not function or works in an anomalous way A cable has been damaged Objects or liquids have got inside a speaker A speaker has been damaged due to heavy impacts or fire 7 Should a speaker emit any strange smell or smoke remove it from the line after having immediately switched the amplifier off 8 Do not connect ...

Page 5: ...nected respecting the amplifier polarity This is important when speakers are installed adjacent one another for instance in the same room Make sure speaker lines are not shorted before turning the amplifier on 13 To prevent inductive effects from causing hum noise and a bad system working speaker lines should not be laid together with other electric cables mains microphone or line level signal cab...

Page 6: ...e equipped with a 5 woofer and a 1 dome tweeter and include an internal transformer with a power selector on the rear side that allows the connection to 70 100 V constant voltage lines WARNING speaker connections should be only made by qualified and experienced personnel having the technical know how or sufficient specific instructions to ensure that connections are made correctly and prevent any ...

Page 7: ...ort as possible for long distances it may be necessary to use cables with large cross section wires The impedance of a single speaker is 8 Ω For example the total impedance of the parallel of two speakers is 4 Ω impedance 8 speaker number NOTES ABOUT 70 100 V CONSTANT VOLTAGE LINES The speaker input voltage Vd shall correspond to the amplifier output voltage Va The sum of nominal power values Pd x...

Page 8: ...osition when linked to a 100 V line POWER SELECTION WHEN LINKED TO 70 100 V CONSTANT VOLTAGE LINE MR 50T MR 50T W only If this speaker is connected to a 100 70 V constant voltage line select its proper power rate by turning its rotary switch by using a screw driver among the values 40 20 10 5 W 100 V or 40 20 10 5 2 5 W 70 V WARNING Do NOT select the 8 Ω position as this may damage the speaker and...

Page 9: ...t cable for the parallel connection of other speakers Applicable wire section from 0 75 mm to 4 mm 1 Connect the line positive wire to the speaker INPUT 2 Connect the line negative wire to the speaker INPUT 3 If necessary connect in the same way the output cable to link other speakers in parallel to speaker LINK and LINK IN OUT ...

Page 10: ...etween ball and joint Use safety screws on both sides WARNING Make sure all speakers are installed in a stable and secure way in order to avoid any conditions that may be dangerous for persons or structures Ensure the support surface walls ceilings etc has the necessary mechanical characteristics to support the speaker weight Before installing every speaker carefully check all components to be use...

Page 11: ...W RMS Nominal input impedance 8 250 500 Ω 1 2 4 kΩ 8 125 250 Ω 0 5 1 2 kΩ Crossover frequency 3 kHz 3 kHz Passive filter 12 12 dB octave 12 12 dB octave Bass reflex tuning frequency 80 Hz 65 Hz High frequency protection Dynamic LICC Dynamic LICC Connector Euroblock removable screw terminals Euroblock removable screw terminals PHYSICAL SPECIFICATIONS Cabinet material Self extinguishing plastic Self...

Page 12: ...12 ENGLISH MR 50T MR 50T W MR 40T MR 40T W ...

Page 13: ......

Page 14: ...interventi o modifiche o riparazioni se non quelle espressamente descritte sul manuale istruzioni Contattare centri di assistenza autorizzati o personale altamente qualificato quando un diffusore non funziona o funziona in modo anomalo un cavo è danneggiato oggetti o liquidi sono entrati in un diffusore acustico un diffusore acustico non è più integro a causa di urti incendio 7 Nel caso che da un ...

Page 15: ...re una corretta riproduzione audio soprattutto quando i diffusori sono collocati in posizione fra loro adiacente o nello stesso ambiente Assicurarsi che la linea dei diffusori acustici non sia in cortocircuito prima di accendere l amplificatore 13 Per evitare che fenomeni induttivi diano luogo a ronzii disturbi e compromettano il buon funzionamento dell impianto le linee diffusori non devono esser...

Page 16: ...e MR 50T W bianco sono dotati di un woofer da 5 ed un tweeter a cupola da 1 è presente un trasformatore interno che permette la loro connessione ad una linea a tensione costante 100 70 V con selettore della potenza sul retro ATTENZIONE per il collegamento dei diffusori acustici si raccomanda di rivolgersi a personale qualificato ed addestrato avente conoscenze tecniche od esperienza od istruzioni ...

Page 17: ...tta al minimo una lunga distanza può comportare l uso di cavi con conduttori aventi sezioni elevate L impedenza di un singolo diffusore acustico è 8 Ω ad esempio il collegamento in parallelo di due diffusori acustici comporta un impedenza complessiva di 4 Ω impedenza 8 numero dei diffusori NOTE PER IL COLLEGAMENTO CON LINEA A TENSIONE COSTANTE 100 70 V La tensione d ingresso del diffusore Vd deve ...

Page 18: ...con collegamento a linea 100 V SELEZIONE DELLA POTENZA CON LINEA A TENSIONE COSTANTE 100 70 V solo MR 50T MR 50T W Se il diffusore acustico è collegato ad una linea a tensione costante si può scegliere la potenza adeguata ruotando il selettore sul retro tramite un cacciavite tra i valori 40 20 10 5 W con tensione 100 V oppure 40 20 10 5 2 5 W con tensione 70 V ATTENZIONE NON selezionare la posizio...

Page 19: ...altri diffusori acustici Sezione utilizzabile dei conduttori da 0 75 mm a 2 5 mm 1 Collegare il conduttore positivo della linea all ingresso INPUT 2 Collegare il conduttore negativo della linea all ingresso INPUT 3 Se necessario collegare allo stesso modo il cavo d uscita destinato alla connessione in parallelo di altri diffusori acustici ai contatti LINK e LINK IN OUT ...

Page 20: ...zioni corrosioni e o parti mancanti o danneggiate che possono ridurre la sicurezza dell installazione INSTALLAZIONE Fissare la staffa alla parete perpendicolarmente utilizzando viti e tasselli scelti in base al tipo di supporto muro 90 L adattatore da fissare al diffusore consente sia l inserimento verticale che quello orizzontale in questo modo il diffusore può essere ruotato di 90 e inclinato or...

Page 21: ...le d ingresso 8 250 500 Ω 1 2 4 kΩ 8 125 250 Ω 0 5 1 2 kΩ Frequenza crossover 3 kHz 3 kHz Filtro passivo 12 12 dB ottava 12 12 dB ottava Frequenza di accordo bass reflex 80 Hz 65 Hz Protezione alte frequenze Dinamica LICC Dinamica LICC Connettore removibile di tipo EUROBLOCK removibile di tipo EUROBLOCK DATI FISICI Materiale del corpo Plastica autoestinguente Plastica autoestinguente Griglia front...

Page 22: ...22 ITALIANO MR 50T MR 50T W MR 40T MR 40T W ...

Page 23: ......

Page 24: ...Emilia Italy Tel 39 0522 274 411 Fax 39 0522 232 428 e mail info rcf it Salvo eventuali errori ed omissioni RCF S p A si riserva il diritto di apportare modifiche senza preavviso Except possible errors and omissions RCF S p A reserves the right to make modifications without prior notice ...