IMPORTANT NOTES

SAFETY AND OPERATING PRECAUTIONS

IMPORTANT

ATTENTION

SAFETY AND OPERATING PRECAUTIONS

Before connecting and using this product, please read this instruction manual carefully 
and keep it on hand for future reference. This manual is to be considered an integral part 
of this product and must accompany it when it changes ownership as a reference for 
correct installation and use as well as for the safety precautions.
RCF S.p.A. will not assume any responsibility for the incorrect installation and / or use of 
this product.

1.   

All the precautions, in particular the safety ones, must be read with special attention, as they 

provide important information.

2.   

Loudspeaker lines (amplifier outputs) can have a sufficiently high voltage (i.e. 100-70 V) to 

involve a risk of electrocution: never install or connect this loudspeaker when the line is alive.

3.   

Make sure all connections have been made correctly.

4.   

Protect loudspeaker lines from damage. Make sure they are positioned in a way that they 

cannot be stepped on or crushed by objects.

5.   

Make sure that no objects or liquids can get into this product, as this may cause a short 

circuit.

6.   

Never attempt to carry out any operations, modifications or repairs that are not expressly 

described in this manual. Contact your authorized service centre or qualified personnel should 
any of the following occur: 1) the product does not function (or works in an anomalous way), 2) 
the cable has been damaged, 3) objects or liquids have got into the product, 4) the product has 
been damaged due to heavy impacts or fire.

7.   

Should the loudspeaker emit any strange odours or smoke, remove it from the line after 

having immediately switched the amplifier off.

8.   

Do not connect this product to any equipment or accessories not foreseen. Also check the 

suitability of the support surface to which the product is anchored (wall, ceiling, structure, etc.) 
and the components used for attachment (i.e. wall plugs, screws, brackets not supplied by RCF, 
etc.), which must guarantee the security of the system / installation over time.

9.   

RCF S.P.A. strongly recommends this product is only installed by professional qualified 

installers (or specialised firms) who can ensure a correct installation and certify it according to 
the regulations in force. The entire audio system must comply with the current standards and 
regulations regarding electrical systems.

10.   

Mechanical and electrical factors need to be considered when installing a professional 

audio system (in addition to those which are strictly acoustic, such as sound pressure, angles of 
coverage, frequency response, etc.).

11.   

Hearing loss. Exposure to high sound levels can cause permanent hearing loss. The 

acoustic pressure level that leads to hearing loss is different from person to person and depends 
on the duration of exposure. To prevent potentially dangerous exposure to high levels of 
acoustic pressure, anyone who is exposed to these levels should use adequate protection 
devices. When a transducer capable of producing high sound levels is being used, it is necessary 
to wear ear plugs or protective earphones. See the technical specifications in the instruction 
manual for the maximum sound pressure the loudspeaker is capable of producing.

12.   

Make sure loudspeaker lines are not shorted before turning the amplifier on.

14.   

The loudspeaker cable shall have wires with a suitable section (twisted, if possible, to 

reduce inductive effects due to surrounding electro-magnetic fields) and a sufficient electrical 
insulation. Refer to local regulations, as there may be additional requirements about cable 
characteristics.
15. Install far from any heat source.
16. Do not use solvents, alcohol, benzene or other volatile substances for cleaning the external 
parts of this product.

5

Summary of Contents for DXT 9000

Page 1: ...MANUALE D USO OWNER MANUAL INSTRUKCJA OBS UGI EOL DXT SYSTEMS END OF LINE EQUIPMENT FOR DXT SYSTEMS...

Page 2: ...to prodotto apparecchi ed accessori non previsti Verificare inoltre l idoneit del supporto es parete soffitto struttura ecc e dei componenti utilizzati per il fissaggio tasselli viti staffe non fornit...

Page 3: ...monitorare con precisione l integrit di una linea di altoparlanti adatto al sistema di lettura di impedenza dei prodotti DXT 1 Svitare le 4 viti che tengono uniti i due gusci 2 Connettere il cavo al m...

Page 4: ...parallelo di linea ed EoL facilmente ricavabile dalla formula di parallelo di due impedenze Zeol 200 Ztot Zlinea x Zeol Zlinea Zeol ATTENZIONE la Zlinea NECESSARIAMENTE l impedenza a 20Hz della linea...

Page 5: ...lso check the suitability of the support surface to which the product is anchored wall ceiling structure etc and the components used for attachment i e wall plugs screws brackets not supplied by RCF e...

Page 6: ...erminator is a product that allow to accurately monitor speakers lines integrity and it is suitable for DXT systems 1 Remove the 4 screws that close the shells 2 Connect the cable to the ceramic termi...

Page 7: ...s parallel and EoL is easily obtainable from the formula of parallel impedances Zeol 200 Ztot Zline x Zeol Zline Zeol WARNING Zline is NECESSARILY the line impedance at 20Hz it is not equal to the imp...

Page 8: ...sprawd r wnie wytrzyma o i stabilno element w do kt rych produkt ma by przymo cowany ciana sufit konstrukcja itp a tak e jako u ywanych do mocowania akcesori w np ko ki rozporowe ruby wkr ty wykonane...

Page 9: ...nikowej jest produktem odpowiednim dla system w DTX umo liwiaj cy precyzyjne monitorowanie linii g o nikowych 1 Usu 4 ruby mocuj ce os on obudowy 2 Pod cz kabel do ceramicznego terminala 3 Zagnie kla...

Page 10: ...yliczenia za pomoc standardowego wzoru do obliczania wypadkowej impedancji czonych r wnole gle Zeol 200 Ztot Zline x Zeol Zline Zeol UWAGA Zline jest WYMAGAN warto ci impedancji linii przy 20 Hz nie j...

Page 11: ...nd fire alarm systems for buildings 7 3 7 6 2 7 7 2 7 8 7 9 8 3 9 10 11 12 13 14 Audible warnings Manual silencing of the voice alarm condition Manual reset of the voice alarm condition Output to fire...

Page 12: ...1234 Int 44 870 626 3142 e mail info rcfaudio co uk RCF France tel 33 1 49 01 02 31 e mail france rcf it RCF Germany tel 49 2203 925370 e mail germany rcf it RCF Spain tel 34 91 817 42 66 e mail info...

Reviews: