RCF DPS3000 User Manual Download Page 20

the rules of sound

RCF SpA:  Via Raffaello, 13 - 42010 Reggio Emilia 

>

 Italy

tel. +39 0522 274411 - fax +39 0522 274484 - e-mail: [email protected]

Salvo eventuali errori ed omissioni.

RCF S.p.A.  si riserva il diritto di apportare modifiche senza preavviso.

Except possible errors and omissions.

RCF S.p.A.  reserves the right to make modifications without prior notice.

10307202

Summary of Contents for DPS3000

Page 1: ...the rules of sound DPS3000 User manual Manuale d uso POWER AMPLIFIER AMPLIFICATORE FINALE DI POTENZA ...

Page 2: ......

Page 3: ... PONTE BRIDGE pag 10 CABLAGGIO DEI CONNETTORI SPEAKON uscite amplificatori pag 11 VENTILAZIONE pag 11 DATI TECNICI pag 11 INDEX ENGLISH SAFETY PRECAUTIONS page 12 DESCRIPTION page 14 UNPACKING AND INSTALLATION page 14 FRONT PANEL page 15 REAR PANEL page 16 OPERATION MODES page 17 STEREO MODE page 17 MONO MODE page 18 BRIDGE MODE page 18 SPEAKON CONNECTOR WIRING amplifier outputs page 19 COOLING RE...

Page 4: ... cavo di alimentazione Un apparecchio avente costruzione di CLASSE I deve essere connesso alla presa di rete con un collegamento alla terra di protezione d Accertarsi che il cavo di alimentazione dell apparecchio non possa essere calpestato o schiacciato da oggetti al fine di salvaguardarne la perfetta integrità e Per evitare il rischio di shock elettrici non aprire mai l apparecchio all interno n...

Page 5: ...attori meccanici ed elettrici da considerare quando si installa un sistema audio professionale oltre a quelli prettamente acustici come la pressione sonora gli angoli di copertura la risposta in frequenza ecc 12 Perdita dell udito L esposizione ad elevati livelli sonori può provocare la perdita permanente dell udito Il livello di pressione acustica pericolosa per l udito varia sensibilmente da per...

Page 6: ...ella protezione Minima impedenza del carico stereo mono 2 Ω Ingressi con connettori XLR Uscite con connettori SPEAKON Installabile in rack 19 2 unità peso non eccessivo per semplificarne il trasporto Limiter limitatore interno disinseribile Alimentatore switching con correzione del fattore di potenza DISIMBALLO ED INSTALLAZIONE Verificare se il cartone per l imballo ed il contenuto hanno subito de...

Page 7: ...la protezione interna a causa di sovraccarico corto circuito deriva termica guasto Il rispettivo canale è temporaneamente disattivato Il funzionamento normale è automaticamente ripristinato non appena il problema è risolto 3 LED Power Indica che l amplificatore è acceso e funzionante 4 LED Bridge Indica che l amplificatore è stato impostato nel modo a ponte 5 Interruttore principale I ON acceso 0 ...

Page 8: ...gresso 32 dB 26 dB guadagno di tensione Utilizzare questo selettore per adattare la sensibilità d ingresso il guadagno di tensione dell amplificatore ad altri apparecchi collegati 1 4 V questa impostazione da scegliere per l utilizzo standard senza processori fissa a 1 4 V il livello del segnale d ingresso richiesto per ottenere la massima potenza d uscita dell amplificatore 32 dB il guadagno di t...

Page 9: ...re il paragrafo Modi di funzionamento q Ingresso per il cavo d alimentazione Collegare il cavo d alimentazione solo ad una presa di rete avente la messa a terra w Aperture per l uscita dell aria calda Non ostruire queste aperture MODI DI FUNZIONAMENTO MODO STEREO Assicurarsi che l amplificatore sia spento prima di porre il selettore MODE su STEREO In stereo i 2 canali funzionano in modo indipenden...

Page 10: ... MODO A PONTE BRIDGE Assicurarsi che l amplificatore sia spento prima di porre il selettore MODE su BRIDGE Nel modo a ponte mono entrambi i canali dell amplificatore funzionano con lo stesso segnale d ingresso ma con fase invertita Questo comporta un raddoppio della tensione d uscita per ottenere una potenza doppia su un carico avente impedenza doppia Entrambi i controlli di livello sul pannello f...

Page 11: ...W 4 Ω 2 x 800 W 8 Ω a ponte 3400 W 4 Ω 2400 W 8 Ω Classe amplificatore Classe HD Risposta in frequenza 20 Hz 20 kHz Distorsione THD 1 kHz 0 05 1 dB sotto il clip Fattore di smorzamento 8 Ω 1000 Slew rate velocità di risposta 55 V μs Rapporto segnale rumore 108 dB Sensibilità d ingresso guadagno di tensione 1 4 V 32 26 dB Impedenza d ingresso 20 kΩ bilanciato 10 kΩ sbilanciato Protezioni temp DC RF...

Page 12: ... a mains socket outlet with a protective earthing connection d Protect the power cable from damage make sure it is positioned in a way that it cannot be stepped on or crushed by objects e To prevent the risk of electric shock never open the product there are no parts inside that the user needs to access 3 Make sure that no objects or liquids can get into this product as this may cause a short circ...

Page 13: ...uneven floors may cause the assembly to overturn 11 There are numerous mechanical and electrical factors to be considered when installing a professional audio system in addition to those which are strictly acoustic such as sound pressure angles of coverage frequency response etc 12 Hearing loss Exposure to high sound levels can cause permanent hearing loss The acoustic pressure level that leads to...

Page 14: ...ility and operating safety Front panel signal clip protect LED indicators Minimum load impedance stereo mono 2 Ω XLR input connectors SPEAKON output connectors 2 unit 19 rack low weight for easy transportation Switchable limiter PFC switched mode power supply UNPACKING AND INSTALLATION Check the carton box and its contents to see if there is any sign of damage should the amplifier be damaged immed...

Page 15: ...nternal protection intervention due to overload short circuit thermal drift fault The respective channel is muted The normal operation will be automatically restored as soon as the problem is solved 3 Power LED When lit it indicates that the amplifier is switched on and operating 4 Bridge LED When lit it indicates that the amplifier is set to the bridge mode 5 Power switch I ON 0 OFF Note amplifie...

Page 16: ...nnected equipments 1 4 V this setting set to 1 4 V the input level required to get the maximum power output from the amplifier use this setting for standard operation with no system controllers 32 dB the amplifier voltage gain is fixed to 32 dB output input ratio will always be 32 dB no matter what the input and the rated output power of the amplifier are 26 dB the amplifier voltage gain is fixed ...

Page 17: ...nnection w Openings for heated air exit Do not obstruct these openings OPERATION MODES STEREO MODE Ensure the amplifier is switched off then set the MODE selector to STEREO In stereo mode the 2 channels operate independently and each front panel level control affects the respective output Minimum nominal load impedance is 2 Ω per output Loudspeakers can be connected to either the SPEAKON output 1 ...

Page 18: ...f the output 1 pins 2 positive 2 negative BRIDGE MODE Ensure the amplifier is switched off then set the MODE selector to BRIDGE In bridge mode mono both amplifier channels work with the same input signal but with inverse phases The result is a doubling of the output voltage in order to get a double power on a double impedance load Both level controls on the front panel must be set to the same valu...

Page 19: ... 8 Ω bridged 3400 W 4 Ω 2400 W 8 Ω Amplifier class Class HD Frequency response 20 Hz 20 kHz THD 1 kHz 0 05 1 dB below clip Damping factor 8 Ω 1000 Slew rate 55 V μs Signal noise ratio 108 dB Input sensitivity voltage gain 1 4 V 32 26 dB Input impedance 20 kΩ balanced 10 kΩ unbalanced Protective circuits Temp DC RFI short circuit Cooling Temperature controlled fan Power supply SMPS Operation voltag...

Page 20: ...522 274411 fax 39 0522 274484 e mail rcfservice rcf it Salvo eventuali errori ed omissioni RCF S p A si riserva il diritto di apportare modifiche senza preavviso Except possible errors and omissions RCF S p A reserves the right to make modifications without prior notice 10307202 ...

Reviews: