1
ENGLISH
FRONT PANEL
1
Channel level control (one per channel).
It is a 41 step control to adjust the output level of the respective amplifier channel.
Turn clockwise to increase the output level (0 dB = max. level);
turn counterclockwise to decrease.
2
LED bar (one per channel)
a.
8 step signal level meter
(-36 dB, -24 dB, -18 dB, -12 dB, -9 dB, -6 dB, 0 dB).
b.
Clip / limiter LED
When lit, it indicates the clipping point and the internal limiter intervention on the respective
channel.
If it stays lit continuously, the input signal level is excessive.
c.
Protection LED
When lit, it indicates the internal protection intervention
(due to overload, short-circuit, thermal drift, fault).
The respective channel is muted.
The normal operation will be automatically restored as soon as the problem is solved.
3
Power LED
When lit, it indicates that the amplifier is switched on and operating.
4
Bridge LED
When lit, it indicates that the amplifier is set to the ‘bridge’ mode.
5
Power switch (I = ON; 0 = OFF)
Note: amplifier soft-start limits start-up surges.
6
Air intakes with grilles and filters
Do not obstruct these air intakes!
Filters are necessary to prevent dust from entering the amplifier. The grilles are removable
for easy filter cleaning. The fan’s variable speed control ensures the proper ventilation
(according to the internal temperature) and low noise operation.
6
1
2342
1
6
5
i
i
Summary of Contents for DPS3000