PHOTOCELL INSTALLATION

A PHOTOCELL MAY BE INSTALLED IN THE FIELD.  
1. Remove door and reflector
2. Remove close up plug on top of fixture
3. Install photocell and wire as per diagram
4. Use photocell rated for your supply voltage

“COM”

PHOTOCELL

WP2FC

CLEANING

CAUTION: Be sure fixture temperature is cool 

enough to touch. Be sure power is off. 

 

Clean reflector and refractor with a cloth moistened 

with non abrasive glass cleaning solution.

RE-LAMPING

CAUTION: Prior to installing, check that the lamp is of 

proper type and wattage. Observe lamp manufacturer’s 

recommendations on lamp operation, burning position and 

ballast type.

1. Disconnect power
2. Make sure fixture and lamp are cool enough to touch.
3. Loosen four screws holding lens.
4. Open by swinging lens down, letting hinge hold lens.
5. Replace lamp.
6. Close lens and tighten screws.

Note:  These instructions do not cover all details or variations 

in equipment nor do they provide for every possible situation 

during installation, operation or maintenance.

FIXTURE

REPLACEMENT LAMPS AND BALLASTS

 

RC Lamp 

ANSI  

           

RC Ballast 

Wattage 

Catalog# 

Code 

           

Catalog#

High Pressure Sodium

35 

LHPS35  S55   BHPSN35

50 

LHPS50  S68   BHPSN50

70 

LHPS70  S62   BHPSN70

100 

LHPS100  S54   BHPSN100

Metal Halide

50PS 

LMH50 

M110  

BMHN50

70PS 

LMH70 

M98   BMHN70

Compact Fluorescent 

Base

26 

LCFL26 

GX24q-3  

BCFL42

32 

LCFL32 

GX24q-3  

BCFL42

42 

LCFL42 

GX24q-4  

BCFL42

TROUBLESHOOTING 

1.  Is the proper lamp is installed? Check the wattage 

and ANSI code on the fixture label against markings 

on the lamp. Refer to Replacement Lamp table 

above for verification.

2.  Make sure the lamp is not defective. Try a lamp 

known to be in operating condition.

3.  Check that the line voltage at fixture is correct. Refer 

to wiring directions.

4.  Is there voltage at the lamp socket? If there is no 

voltage, check all connections.

5.  Is the fixture grounded properly?
6.  If used, is the photocell functioning properly?

WP1 INSTALLATION INSTRUCTIONS

WP1F-IN 0113 RCL

Thank you for buying RC lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. 
Call the Marketing Department at 888-722-1000 or email: [email protected]

Easy Installation & Product Help

Tech Help Line

Call our experts 888 722-1000

rclighting.ca

Visit our website for product info

email

Answered promptly [email protected]

©2012 RC LIGHTING, LLC

Northvale, New Jersey 07647 USA

Summary of Contents for WP1

Page 1: ...s are routed and secured min 3 inches away from ballast use wire rated for at least 90 C 1 Connect the appropriate voltage fixture lead to the HOT supply lead 2 Connect the COM fixture lead to the COMMON supply lead 3 Fixture ground screw must be connected to supply ground 4 All unused leads must be capped and insulated Drill Template Lag Bolt Locations WP1 INSTALLATION INSTRUCTIONS IMPORTANT READ...

Page 2: ...g High Pressure Sodium 35 LHPS35 S55 BHPSN35 50 LHPS50 S68 BHPSN50 70 LHPS70 S62 BHPSN70 100 LHPS100 S54 BHPSN100 Metal Halide 50PS LMH50 M110 BMHN50 70PS LMH70 M98 BMHN70 Compact Fluorescent Base 26 LCFL26 GX24q 3 BCFL42 32 LCFL32 GX24q 3 BCFL42 42 LCFL42 GX24q 4 BCFL42 TROUBLESHOOTING 1 Is the proper lamp is installed Check the wattage and ANSI code on the fixture label against markings on the l...

Page 3: ...rdement aux fils d alimentation et de mise à la terre consultez les directives de raccordement 5 Remettez le réflecteur en place puis installez la lampe Refermez le couvercle et serrez les quatre vis 6 Afin de garantir l étanchéité s assurer que tous les orifices de montage de conduit bouchons etc sont scellés au moyen d un produit d étanchéité à base de silicon ENDROIT 1 Fixez le luminaire au mur...

Page 4: ...elle correctement si le luminaire en est doté NETTOYAGE Attention S assurer que le luminaire est suffisamment froid au toucher S assurer que le courant est coupé Nettoyer le réflecteur et le réfracteur avec un chiffon humecté d une solution de nettoyage de verre non abrasive REMPLACEMENT DE LA LAMPE Attention Avant l installation s assurer que la lampe est du type et de la puissance appropriés Res...

Reviews: