21
MORE PAD INDOOR
8. POWER SUPPLY DRIVERS
•
The PAD INDOOR must be supplied via the system’s power supply DRIVERS;
•
DRIVER 320, DRIVER 600 and DRIVER 1000 are rectifier transformers with the output line, 36
VDC side,protected against short circuit, overload, overvoltage and overtemperature;
•
The DRIVER 320, DRIVER 600 and DRIVER 1000 allow adjustment of the output voltage value by
means of a specific trimmer;
DRIVER 320
It is a watertight version of the equipment to be preferred if:
•
The location must be in a humid place and/or with the possibility of surface condensation;
•
The environment in which it is located lacks or has limited ventilation for the correct operation of
the equipment (false ceiling, built-in electrical box, etc.);
•
A maximum of 10 m of PAD mat must be fed.
•
When the heating system is installed in a special environment where SELV safety is required,
such as wet rooms or bathrooms.
FG (Green/Yellow)
AC/L(Brown)
AC/N(Blue)
+V(Red)
HLG-320H
-V(Black)
DIM-(White)
DIM+(Blue)
LOAD (%)
90 (HORIZONTAL)
-40
0
-25
20
45
55
65
75
20
40
60
80
100
Tcase (°C)
LOA
D
(%
)
-40
-25
0
-10
15
30
50
60
70
20
40
60
80
100
(HORIZONTAL)
230VAC
110VAC
AMBIENT TEMPERATURE,Ta (°C)
A
IN line power supply
230 VAC line connection
AC/L brown
AC/N blue
FG
yellow- green
C
Connection PAD INDOOR Line
300 W
-V black
+V red
OUT power supply PAD
D
Output voltage adjustment trimmer highlighted in red.
Replace the cap to restore the IP grade.
adjustment trimmer