LIF200 User Manual
14
Remote Connection Port Number
: default
3002
, range 0 to 65535.
Remote Host IP Address
: default
0.0.0.0
.
If your device is configured as active (to report real-time status to a remote and data reception by the peer
needn‟t be guaranteed) then you can set LIF-200 as UDP Client. Be sure the value „Remote Connection
Port Number‟ is set to the same value that your remote control application is using and set the correct
value of „Remote Host IP Address‟.
4.2.
Serial Type
The LIF-200 supports two serial types: RS232, and RS485, these types are listed in the drop-down menu
for the „Serial Type‟ setting. Each setup screen and available features will differ depending on what
„Serial Type‟ you selected. The default setting is
RS232
.
RS232/RS485
Baud Rate
: default
9600
, range 1200bps to 230.4Kbps, „Others‟.
If no suitable Baud Rate appears in the drop-down menu chose “Others” and enter your own value.
Data Bits
: 5, 6, 7,
8
(default).
Parity Check
:
None
(default), even, odd, mark, space.
Stop Bits
:
1
(default), 2.
Flow Control
:
None
(default), CTS/RTS (or Hardware), XON/XOFF (or Software).
Force Packet Transmit Time (ms)
: default
0
, range 0 to 65535.
You can adjust the timing for transmitting an Ethernet packet. In order to get all of your data in one
packet you can tune this setting value to fit the data length of your device.