INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

1

2

3
4

5

6

7

9

10

11

12

8

13

14

15

17

16

23

8

19

16

8

15

21

20

29

28

27

26

25

24

14

35"

36"

17"

3"

18

Summary of Contents for RBA8910-500 Series

Page 1: ...ww rbagroup co nz 1 8 INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS RBA8910 500 Series Sensor Push Button Operated Outdoor Bottle Filler Date 17 06 14 Model Outdoor Bottle Filler Pedestal Mounted Supercedes all previous 22005 22108 22007 Lic W1186 1186 022317 ...

Page 2: ...s are in inches mm 2 Dimensions shown are for recommended adult height Adjust vertical dimensions as necessary to comply with federal state local codes 3 Water lines from chiller to foundation should be covered with sponge foam rubber or ice water type insulation of adequate thickness OUTDOOR PEDESTAL MOUNTED BOTTLE FILLER Meets US ADA requirements 521 4 1327 313 4 806 23 4 71 ACCESS PANEL 155 8 3...

Page 3: ... the concrete is available 3 Feed the 7 8 OD flexible drain tube into the open ended drain tube Connect the male BSP fitting to a potable water supply Then tilt the unit into place making sure that the tubing is not pinched or kinked Secure the base flange to the mounting pad 4 Connect the battery pack to matching battery wire terminals When connected the unit is active 5 Test for leaks and proper...

Page 4: ...SERTING THE TUBE 1 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep 2 Pull on the fitted tubing to ensure it is secure Tube should not come free from the fitting Water test the connection assembly prior to leaving the site to ensure there are no leaks DISCONNECTING THE TUBE To disconnect the tube from the fitting ensure that the water l...

Page 5: ...connection from sensor to solenoid b There is debris or scale in the solenoid assembly Remove solenoid pull out plunger and spring Clean with scale remover solution c There is debris or scale in the center or two holes in convolution of the water diaphragm Remove and clean Cleaning Maintenance Guide FOR POWDER COATED UNITS Units should be cleaned using a mild soap solution with a sponge or cotton ...

Page 6: ...Foam Tape 24 2566 025 002 Pushbutton Sub Assy 6 7013 057 002 Nano spacer Assy 25 2570 130 001 Replacement 9 12 V DC Solenoid Valve 7 7013 009 001 Nano Sensor Spacer 26 0112 011 000 10 32 x 3 8 CNTR RJCT Screw 8 2169 000 000 1 4 OD Blue Tubing 27 2570 101 001 Replacement Non Metering Air Trol Valve 9 0124 033 000 8 32 Self Tapping Screw 28 7013 046 001 6 AA Battery Pack 10 7000 006 000 Drain Adapte...

Page 7: ...8 778 www rba com au New Zealand 0800 722 111 www rbagroup co nz 7 8 INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS 1 2 3 4 5 6 7 9 10 11 12 8 13 14 15 17 16 23 8 19 16 8 15 21 20 29 28 27 26 25 24 14 35 36 17 3 18 ...

Page 8: ...and 0800 722 111 www rbagroup co nz 8 8 INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS Contact Us 1300 788 778 www rba com au sales rba com au SYDNEY Level 1 32 Frederick St Oatley 2223 MELBOURNE Unit 9 56 Norcal Rd Nunawading 3131 BRISBANE Unit 13 54 Nealdon Dr Meadowbrook 4131 0800 722 111 www rbagroup co nz sales rbagroup co nz AUCKLAND 300 Richmond Road Grey Lynn 1021 Notes ...