10.3
Command Set
P ... Poll, B ... Burst, S ... Set, N ... Notification
FORMATSET
Description
Char Format P S Example
Poll parameter
?
?X
?T
Set parameter
=
X=...
E=0.85
Set without Save
#
X#
E#0.85
FORMAT RESPONSE
Description
Char Format P S Example
Acknowledge
!
!XXX
!T020.0
Error message
*
*Syntax error
COMMAND LIST
Description
Char Format P S Legal values
Factory default
Device adjustment
gain**
DG n.nnnn
0.8000 … 1.2000
1
Device adjustment
offset **
DO nn.n
-20.0 … +20.0°C
0
Device special Info.
DS
XXX
z.B. !DSRAY
DSRAY
Emissivity internal
E n.nnn
0.100 … 1.100
0.95
Valley hold time
F nnn.n
0.000 … 998.9 s
(999 = infinite)
0
Average time
G nnn.n
0.100 ... 999 s
0
Top of mV range
H nnnn.n
0 … 500°C
500
Sensor/head ambient
I
nnn.n
In current scale (°C/°F)
Relay alarm output
control
K n
0=Alarm Off
1=Alarm On
2= Target, normal open
3= Target, normal close
4= Head, normal open
5= Head, normal close
6= Over current protect*
Bottom of mV range
L nnnn.n
-
20 … 480°C
-20
Output voltage***
O nnn
0-100=% of full range
255=controlled by unit