4.5 Multiplexers Tap Changer Interface
4.5.1 General Description
Every winding system could have its own tap changer. They are easy to control with
Multiplexers; every Multiplexer is equipped with a powerful tap changer interface.
Hardware:
2 relay contacts, normally open, 250V / 3A
2 relay contacts, normally open, 60V / 3A
2 digital in, prepared for tap changer use
2 digital in, ready for general use.
2 digital out, darlington open collector, to control external relays.
Software:
Multiplexers tap changer interface can be easily controlled by the Winding
Resistance Meters remote interface. A local control of tap changer interface is not
available.
NOTE
⇒
To control the tap changer interface, please see the latest version of
‘90104-X.XX Command Set WR-xx.pdf’ for commands and description.