4.

 

Technical Specification

 

 

               WARRIOR 24 

                                  WARRIOR 48

 

 

Input Voltage

 

110-254V AC or 18-48V AC/18-69V DC or 12V DC

 

Consumption

 

68W max

 

136W max

 

Consumption

 

(Emergency  variant)

 

 

71W max

 

139W max

 

Power Factor

 

>0.95

 

Mains Frequency

 

50/60Hz

 

Inrush Current (Ipeak @ 50%)

 

40A 

t < 300µs

 

Total Harmonic Distortion (230Vac full load)

 

<10%

 

IP Rating

 

IP66/67

 

 

Weight Environment

 

 

Standard - 8kg (17.6lbs) 

Emergency - 10Kg (22lbs)

 

 

Standard - 16kg (35.2lbs) 
Emergency - 20Kg (44lbs)

 

Weight Environment

 

(Emergency  variant)

 

 

11.5kg (25.3lbs)

 

 

21kg (46.3lbs)

 

Dimensions Dimensions

 

See previous pages for line diagrams

 

 

 

 

Summary of Contents for WARRIOR 24

Page 1: ...The WARRIOR series of industrial floodlights are specialist devices for use in industrial operating environments The units must be installed in accordance with these instructions and must be installed...

Page 2: ...eads such as PSU cover and external earth points During installation ensure exterior surface of the product is not in direct contact with a dissimilar metal such as galvanised steel If so fit a nylon...

Page 3: ...ation Mounting WARRIOR Unit 1 To meet the requirements of certification a MINIMUM of 2 fixing points must be used the fixing points must be suitable for the conditions of use Raytec recommend using M8...

Page 4: ...epending on the mounting application where possible the cable glands should be kept to the bottom of the floodlight It is very important that the red fibre washers are fitted between the WARRIOR housi...

Page 5: ...UK Europe Tel 44 0 1670 520055 Americas Tel 1 613 270 9990 www raytecled com 5 Typical wiring diagram standard luminaires Typical wiring diagram emergency luminaires...

Page 6: ...ck connection 8 Emergency WARRIOR floodlights may have a single green LED fitted adjacent to the incoming cable glands when illuminated the green LED indicates that the emergency system is healthy 9 T...

Page 7: ...and make the equipment dangerous 3 Isolate the WARRIOR unit from the mains supply and allow to cool before carrying out any maintenance work 4 The unit has 2 independent power supplies in the event t...

Page 8: ...onsumption Emergency variant 71W max 139W max Power Factor 0 95 Mains Frequency 50 60Hz Inrush Current Ipeak 50 40A t 300 s Total Harmonic Distortion 230Vac full load 10 IP Rating IP66 67 Weight Envir...

Page 9: ...put is turned on at the source 4 On emergency variants check fuse to ensure it has not blown 5 If LED panel fails to light is it possible to identify if problem is with LED panel or power supply by sw...

Page 10: ...ing Americas Tel 44 0 1670 520055 sales raytecled com Raytec Ltd Unit 15 Wansbeck Business Park Rotary Parkway Ashington Northumberland NE63 8QW United Kingdom raytecled com Raytec Americas Tel 1 613...

Reviews: