background image

6

raytecled.com

Raytec Global Tel: +44 (0) 1670 520055

Americas Tel: +1 613 270 9990

i16

w16

i8

w8

i6

i4

w4

i2

w2

10°

500m 

(1640ft)

250m 

(820ft)

350m 

(1148ft)

180m 

(591ft)

200m 

(656ft)

144m 

(472ft)

110m 

(361ft)

78m 

(256ft)

60m 

(197ft)

35°

250m 

(820ft)

125m 

(410ft)

165m 

(541ft)

95m 

(312ft)

120m 

(394ft)

78m 

(256ft)

65m 

(213ft)

54m 

(177ft)

40m 

(131ft)

60°

135m 

(443ft)

70m 

(230ft)

95m 

(311ft)

50m 

(164ft)

70m 

(230ft)

54m 

(177ft)

35m 

(115ft)

36m 

(118ft)

25m 

(82ft)

80°

105m 

(344ft)

48m 

(157ft)

70m 

(230ft)

35m 

(115ft)

50m 

(164ft)

36m 

(118ft)

25m

(82ft)

24m 

(79ft)

20m 

(66ft)

120°

65m 

(213ft)

35m 

(115ft)

45m 

(148ft)

25m 

(82ft)

30m 

(98ft)

24m 

(79ft)

18m 

(59ft)

18m 

(59ft)

12m 

(39ft)

Consumption 100W max 84W max 46W max 42W max 25W max 13W max 24W max 10W max 11W max

Input

24V AC/DC 

12-24V AC/DC 

12-24V AC/DC 

12-24V AC/DC 

Weight

3.1kg  (6.8lbs)

1.65kg (3.61lbs)

950g  (2.1lbs)

600g  (1.3lbs)

Number of LEDs

48

24

12

9

12

6

6

Environment

IP66

IP66

IP66

IP66

Dimensions

180 x 277 x 75mm  

(7”x11”x2.9”)

135 x 180 x 68mm 

 (5”x7”x3”)

100 x 135 x 66m  

(4”x5”x2.5”) 

75 x 100 x 64mm  

(3”x4”x2.5”)

Cable Length 

2.5m

2.5m

2.5m

2.5m

2.5m

2.5m

2.5m

2.5m

2.5m

VARIO2 Specifications Table 

Infra-Red Series & White-Light Series 

• 

For i16; w16; i8; w8 the supply to the units should be limited to/ fused at 5A

• 

For i6; w4 the supply to the units should be limited to/ fused at 3.15A

• 

For i4; i2; w2 the supply to the units should be limited to/ fused at 1.6A

For IR940nm Distances / Information contact Raytec

Optional Bracketry 

(not to scale - other Bracketry also available)

Wall Mount

VUB-Pole

Dome Mount

VUB-Plate 

(Various Sizes)

Ptz Mount

VUB-Wall

Pole Mount

VUB-PSU Plate

Summary of Contents for VARIO2 series

Page 1: ...Information Page 2 Installation Steps Page 3 Factory Defaults Complete Set up and Installation Page 5 Standard Bracketry Page 6 Specifications Table Page 7 8 Troubleshooting Box Contents VARIO2 LITE...

Page 2: ...ard distance is 1500mm For VAR2 LTE w16 1 and VAR2 LTE w4 3 VAR2 LTE w8 2 3 variants hazard distance is 1840mm Eye Safety Other Wavelengths Contact Raytec The Illuminator is Class lll for insulation I...

Page 3: ...lenses will be clearly marked with the angle which they will produce when inserted into VARIO2 Please handle ILS lenses with care and do not touch optical film Only 1 ILS lens can be inserted into th...

Page 4: ...TTL input Volt free input dry contact Non polarity sensitive short circuit light on TTL input Orange TTL ve Purple TTL ve GND 0V Light on 3V Light off Step 5 Photocell following output White Yellow Vo...

Page 5: ...80mm 104mm 148 5mm 53mm 75mm Step 6 Photocell adjust The photocell can be adjusted by a potentiometer accessed by removing the baseplate The default for the photocell is 15 Lux on 30 Lux off When the...

Page 6: ...x 11W max Input 24V AC DC 12 24V AC DC 12 24V AC DC 12 24V AC DC Weight 3 1kg 6 8lbs 1 65kg 3 61lbs 950g 2 1lbs 600g 1 3lbs Number of LEDs 48 24 12 9 12 6 6 Environment IP66 IP66 IP66 IP66 Dimensions...

Page 7: ...t Check current is being drawn amount of current will depend on power setting of unit Please note use appropriate multimeter depending on how the unit is being powered AC or DC To test this you must e...

Page 8: ...c illuminator or remote control is still not delivering the required performance please contact us for further assistance UK Europe Tel 44 0 1670 520055 Americas Tel 1 613 270 9990 Note The light sour...

Reviews: