7.  Disable Remote Control Set-up

The security features implemented in the VARIO2 illuminator and 

VARIO2 remote control are designed to ensure that the system 

cannot be programmed by unauthorized personnel. The system 

is automatically in programming mode once the illuminator is 

powered up. Once the installer/user has finished programming the settings 

of the VARIO2 illuminator, they can choose to lock-in these settings by 

pressing the ‘Disable Remote Set-up’ button.

To disable the remote control, continuously press the ‘Disable Remote 

Control’ button for 4 seconds. When the remote control is disabled, and the 

illuminator is in Operating mode the RHS LED indicator is Off. After 7 days 

of continuous power the illuminator will automatically disable the remote 

and change to Operating mode.

Please note: To enable programming mode again after remote set-

up has been disabled, the VARIO2 illuminator must be powered off 

(for at least 10 seconds) then on again - the illuminator will then 

automatically re-enter programming mode.

(If a PIN security code has been set, further actions are required to enable 

programming mode – Please refer to the illuminator Instruction Guide)

We would normally recommend disabling remote set-up once you have 

finished programming an individual VARIO2 illuminator and are satisfied that 

it is delivering the required operating performance. This will help to avoid 

tampering and the possibility of receiving commands when programming 

other units in close proximity.

Summary of Contents for VARIO2 series

Page 1: ...ry Input 4a Telemetry TEL Remote Switching 4b Telemetry DIM Remote Dimming 4c Timer Function 5 LED Status Indicators Enable Disable 6 Restore Factory Default Settings Stored Memory 7 Disable Remote Co...

Page 2: ...are available in Programming Mode Note If a PIN has been set the unit will not enter programming mode on power up refer to section 10 for more details Programing mode will automatically be disabled af...

Page 3: ...Off 4a TEL Select this option to turn lamp on off remotely from a remote input or switch This is the factory default setting 4b DIM Select DIM to dim lamp remotely from an input or switch First input...

Page 4: ...inator The LEDs provide important operating and status information The Infra Red receiver for the Remote Control commands is also on the base of the unit and the Remote Control should be pointed in th...

Page 5: ...N Remote control IR receiver problem Max VRC distance is 8m 26ft FLASHING AMBER Indicates the unit is in programming mode Programming Mode Only SOLID AMBER Indicates that a valid command is being rece...

Page 6: ...e Programming mode automatically disabled after 7 days or until the user actively disables the programming mode or the unit times out 30 minutes after any press of the manual buttons on the illuminato...

Page 7: ...ux On 30 Lux Off IMPORTANT NOTE When the Photocell is disabled VARIO2 VARIO2 POE Premium The illuminator will turn on off from a telemetry input regardless of ambient lighting conditions VARIO2 POE no...

Page 8: ...wires Snip the end of the cable and then use the two core cable as normal VARIO2 POE not premium Telemetry input not available Illuminator will automatically be controlled by the photocell VARIO2 Hyb...

Page 9: ...put is first applied it will dim the light until the input stops orange and purple wires no longer joined the illuminator will then stay at that brightness level Further telemetry input will continue...

Page 10: ...period and have the unit operate under standard telemetry conditions press Timer Disabled Note The timer only functions when the Telemetry Input Wires are used with a remote switch alarm system PIR de...

Page 11: ...is status indicator function can be switched on and off by pressing the STATUS button This is the only button that has two states It is possible for this function to be enabled disabled even if progra...

Page 12: ...continuously for at least 4 seconds This is to avoid the possibility of activating this feature accidentally Note Restoring to factory settings is not possible if a PIN has been set The factory defau...

Page 13: ...e the RHS LED indicator is Off After 7 days of continuous power the illuminator will automatically disable the remote and change to Operating mode Please note To enable programming mode again after re...

Page 14: ...ntrol Set Up button is pressed again and held for 4 seconds the manual buttons will be disabled When completed this is shown by both indicator LEDs flashing RED Note This command can only be used with...

Page 15: ...Red source is pointing at the remote receiver which is on the bottom of the unit Ensure that there is a clear line of site between the unit and remote with no possible obstructions In extreme sunligh...

Page 16: ...ssales rayteccctv com www rayteccctv com Check battery on remote CR2025 Test 3 volt battery and replace if necessary Ensure battery has clean contacts Remote failure test with new remote If the remote...

Reviews: