1. Safety instructions

1.  Read this leaflet carefully before commencing to install the SPARTAN unit and retain 

it for future use. Installation can only be carried out by suitably qualified personnel.

2.  Check the certification and “T” rating to ensure that the mains supply and the 

ambient temperature present is suitable for the unit being installed.

3.  If the SPARTAN unit is to be installed in areas of high vibration, please consult 

with Raytec.

4.  Externally the SPARTAN unit housing is constructed from marine grade 

aluminium,  and toughened glass, stainless steel brackets/fasteners and 
silicone gaskets, internally there are many non metallic components. The end 
user must ensure that these materials are suitable for the environment the 
SPARTAN unit will be installed in; Zone 1 and Zone 2 Hazardous areas.

5.  Check certification nameplate on side of floodlight to ascertain type of threaded 

cable entry on the luminaire. Select suitably certified ATEX/IEC Ex /UKEX cable 
glands and stopper plugs, these must be parallel thread, have a minium of 5 full 
thread engagement and be of a medium/fine tolerance to ISO965-1 and ISO965-
3. The cable entry devices selected must maintain the IP rating of the luminaire

6.  The incoming mains cable should not exceed a temperature rise of 20

°

C above 

the ambient conditions; select suitable cable. 

7.  When the unit is installed correctly and in accordance with these installation 

instructions it will not harm humans or animals.

8.   Before installing emergency luminaires please check the last charge date of 

the battery. This is shown on the external product packaging and also on the 
battery label, alternatively consult date shown on the declaration at the back of 
this leaflet. If the last charge date was in excess of 3 months (if stored at 5

°

C to 

25

°

C) or 1 month (if stored outside this range) from date of installation, please 

consult Raytec document 0010-D-00001 Battery Handling Guide

        

!

Install in a well 

ventilated area

Do not continually 

stare at lamp

Isolate mains before  

removing cover

1.5m

Summary of Contents for SPARTAN 12

Page 1: ...PARTAN series of explosion protected floodlights are specialist devices certified for use in specific operating environments The units must be installed in accordance with these instructions must be c...

Page 2: ...ype of threaded cable entry on the luminaire Select suitably certified ATEX IEC Ex UKEX cable glands and stopper plugs these must be parallel thread have a minium of 5 full thread engagement and be of...

Page 3: ...ing SPARTAN Unit 1 To meet the requirements of certification a MINIMUM of 2 fixing points must be used the fixing points must be suitable for the conditions of use Raytec recommend using M8 Marine Gra...

Page 4: ...ending on the mounting application where possible the cable glands should be kept to the bottom of the floodlight It is very important that the red fibre washers are fitted between the SPARTAN housing...

Page 5: ...ww raytecled com UK Europe Tel 44 0 1670 520055 Americas Tel 1 613 270 9990 Typical wiring diagram standard luminaires Typical wiring diagram emergency luminaires WHITE RED WHITE RED WHITE RED WHITE R...

Page 6: ...k connection 8 Emergency SPARTAN floodlights may have a single green LED fitted adjacent to the incoming cable glands when illuminated the green LED indicates that the emergency system is healthy 9 Th...

Page 7: ...ons or spare parts will invalidate certification and make the equipment dangerous 3 Isolate the SPARTAN unit from the mains supply and allow to cool before carrying out any maintenance work 4 The unit...

Page 8: ...Environment Emergency variant N A 11 5kg 25 3lbs 21kg 46 3lbs Dimensions Dimensions See previous pages for line diagrams ATEX and IECEx and UKEX Rating See below CML13ATEX3007 or IEC Ex CML14 0001 or...

Page 9: ...put is turned on at the source 4 On emergency variants check fuse to ensure it has not blown 5 If LED panel fails to light is it possible to identify if problem is with LED panel or power supply by sw...

Page 10: ...nt emergency Certification CML Body New Port Road Ellesmere Port CH65 4LZ Certificate Zone 1 CML13ATEX3007 IEC Ex CML14 0001 CML21UKEX3099 Zone 2 CML17ATEX4231 IEC Ex CML17 0135 CML21UKEX4106 ATEX Qua...

Page 11: ...ty Requirements has been assessed by reference to the following harmonised designated standards EN 60079 0 2018 EN 60079 7 2015 A1 2018 EN 60079 18 2015 A1 2017 EN 60079 31 2014 EN 60079 1 2014 And al...

Page 12: ...UK Europe T 44 0 1670 520055 F 44 0 1670 819760 hazsales raytecled com Americas Toll Free T 1 888 505 8335 ushazsales raytecled com www raytecled com...

Reviews: