1. Safety instructions
1. Read this leaflet carefully before commencing to install the SPARTAN unit and retain
it for future use. Installation can only be carried out by suitably qualified personnel.
2. Check the certification and “T” rating to ensure that the mains supply and the
ambient temperature present is suitable for the unit being installed.
3. If the SPARTAN unit is to be installed in areas of high vibration, please consult
with Raytec.
4. Externally the SPARTAN unit housing is constructed from marine grade
aluminium, and toughened glass, stainless steel brackets/fasteners and
silicone gaskets, internally there are many non metallic components. The end
user must ensure that these materials are suitable for the environment the
SPARTAN unit will be installed in; Zone 1 and Zone 2 Hazardous areas.
5. Check certification nameplate on side of floodlight to ascertain type of threaded
cable entry on the luminaire. Select suitably certified ATEX/IEC Ex /UKEX cable
glands and stopper plugs, these must be parallel thread, have a minium of 5 full
thread engagement and be of a medium/fine tolerance to ISO965-1 and ISO965-
3. The cable entry devices selected must maintain the IP rating of the luminaire
6. The incoming mains cable should not exceed a temperature rise of 20
°
C above
the ambient conditions; select suitable cable.
7. When the unit is installed correctly and in accordance with these installation
instructions it will not harm humans or animals.
8. Before installing emergency luminaires please check the last charge date of
the battery. This is shown on the external product packaging and also on the
battery label, alternatively consult date shown on the declaration at the back of
this leaflet. If the last charge date was in excess of 3 months (if stored at 5
°
C to
25
°
C) or 1 month (if stored outside this range) from date of installation, please
consult Raytec document 0010-D-00001 Battery Handling Guide
!
Install in a well
ventilated area
Do not continually
stare at lamp
Isolate mains before
removing cover
1.5m