10.3
Lighting commands
The lighting command codes and their meanings are described below. The
upper-case commands are shown, followed by lower case letters denoting
the numeric argument.
Note any changes using these commands are not saved permanently until the
AW
command has been issued.
Set switched mode
The output is set to switched mode at a specified percentage of full
brightness.
RW1,s
Where:
s
= brightness setting in percent (0 to 100)
Set pulse mode
The output can be set to pulse on a trigger. The delay from trigger to start of
pulse, the length of pulse, and the brightness are all configurable.
An error is generated if the brightness setting requires a current greater
than 20A, or if the combination of pulse width and setting is not allowed.
RTc,p,d,s
RTc,p,d,s,r
Where:
c
output: 1 for light strobe output, 2 for trigger output
signal.
p
pulse width in milliseconds (0.01 to 3)
d
delay from trigger to pulse in milliseconds (0.01 to 999)
s
brightness setting in percent (0 to 100)
r
re-trigger delay in milliseconds (optional).