
14
Note:
The peak of these current pulses is typically 8 Amps, and that mean current
consumption is typically 5 Amps once the power-up sequence is complete, and
the VTR4 is running at maximum brightness and duty cycle.
6.2
Trigger input
The trigger input is opto-isolated. The opto-isolator isolates voltages up to 50V.
Signal
Function
TRGI
–
Trigger input negative
TRGI +
Trigger input positive
The trigger input circuit is as follows:
The trigger input circuit operates as follows:
When a voltage of 5V to 24V is applied across TRGI
–
and TRGI +, the trigger
input is logic 1 (on). When a voltage of 0V to 2V is applied across TRGI
–
and
TRGI +, the trigger input is logic 0 (off).
To see how to set up the light to trigger on a 0-1 transition (rising edge) or a 1-0
transition (falling edge), refer to Section 7.5, Trigger input.
The trigger input typically sinks 2mA when a 5V trigger is applied, and 12mA
when a 24V trigger is applied. The trigger input current will scale linearly
between these two extremes.
6.3
Trigger output
The trigger output is opto-isolated. The opto-isolator isolates voltages up to
50V.
Signal
Function
TRGO
–
Trigger output negative
TRGO +
Trigger output positive
Summary of Contents for PULSESTAR VTR4
Page 1: ...PULSESTAR VTR4 Installation Guide Issue 006...
Page 2: ...For your notes...
Page 38: ...34...