16
6
Connecting the VCT6
All connections to a standard VCT6 are made through an unterminated, screened
12 core cable. The length of this cable is typically 2000mm ± 100mm. The
terminations for this cable are explained in Section 6.1, Ethernet variants and
Section 6.2, RS232 variants.
Alternatively, the unit may be fitted with a 3000mm ± 100mm unscreened
cable terminated with two Molex Mini-fit Jr connectors. The terminations for
this cable are explained in Section 6.2, RS232 variants.
6.1
Ethernet variants
The wires of the 12-core cable are connected as follows:
Wire colour
Function (Ethernet)
Black
Blue
Power supply
–
Red
Red & Blue
Power
White
Trigger in
–
Brown
Trigger in +
Grey
Ethernet Tx +
Pink
Ethernet Tx
–
Yellow
Ethernet Rx +
Green
Ethernet Rx
–
Grey & Pink
Trigger out
–
Violet
Trigger out +
Screen
Case ground
6.2
RS232 variants
The wires of the 12-core cable are connected as follows:
Wire colour
Function (RS232)
Black
Blue
Power supply
–
Red
Turquoise
Power
White
Trigger in
–