background image

www.rayteccctv.com

Raytec Global Tel: +44 (0) 1670 520055

Americas Tel: +1 613 270 9990

4

!

!

CAUTION:  Red    =  +ve 

Black  =  -ve

(polarity sensitive)

CAUTION:  Ensure correct 

polarity of all connectivity

Mount illuminator 

Mount PSU/ Controller: 
Mount PSU on wall/flat 

surface with glands  

facing down

Connect Illuminator to PSU/ 

Controller

2

5

3

6

1

4

Mains/ L

V Input

3

1

2

Installation

(see diagrams on page 8 for further detail)

Illuminator Polarity

12V DC Power Output

Input

Trigger 1

Trigger 2

Lamp 1

Lamp 3

Lamp 2

Lamp 4

-

+

-

+

-

+

-

+

-

+

-

+

-

+

-

+

Connect input trigger to 

controller’

Connect Controller to power

Optional network connectivity 

Network 

Connectors 

(optional: for 

troubleshooting 

or experienced / 

expert users)

Summary of Contents for PULSESTAR Series

Page 1: ...gle via Adaptive Illumination AI if required 3b Change angle of diffuser if required 4 Tighten all fixings Eye Safety EN62471 Risk Group 2 Do NOT stare at the lamps Use appropriate protection Hazardou...

Page 2: ...nced and expert users may request the Engineering Guide which provides information on changing the set up and operation of the unit Pulsestar illuminators deliver powerful pulsed lighting for transpor...

Page 3: ...ing of the product Inter Changeable Lens System Wiring 1 Mount Illuminator 2 Connect Illuminator to low voltage input 12 24V AC DC IMPORTANT For Vario 16 variants 24V only AC DC 3 Complete configurati...

Page 4: ...all flat surface with glands facing down Connect Illuminator to PSU Controller 2 5 3 6 1 4 Mains LV Input 3 1 2 Installation see diagrams on page 8 for further detail Illuminator Polarity 12V DC Power...

Page 5: ...r optimum image performance Reduces performance May cause hot spots Best performance Camera Adjust vertical angle Adjust horizontal angle via Adaptive Illumination AI if required Adjust the angle of d...

Page 6: ...www rayteccctv com Raytec Global Tel 44 0 1670 520055 Americas Tel 1 613 270 9990 6 Specifications...

Page 7: ...rayteccctv com Raytec Global Tel 44 0 1670 520055 Americas Tel 1 613 270 9990 7 NOTE Ensure operating voltage is correct for unit being installed DO NOT INPUT MAINS VOLTAGE INTO LOW VOLTAGE CONTROLLE...

Page 8: ...le High Voltage x72 and x96 4 Channel Controller up to 4 lamps 2 triggers 12V DC Power Output Network Connector optional Mains Input 100V to 230V AC Auto Sensing Trigger 1 Trigger 2 if fitted Lamp 1 L...

Page 9: ...ontroller 4 lamps 2 triggers 2 Channel Controller 2 lamps 1 triggers Network Connector optional Network Connector optional 12V DC Power Output 12V DC Power Output Low Voltage Input 24V DC Mains Input...

Page 10: ...p 1 Lamp and Controller Check polarity of lamp connection RED ve BLACK ve Check supply input Check fuse is intact Check trigger polarity is correct 3V 24V DC rising edge ve pulse on Check trigger sour...

Page 11: ...icas Tel 1 613 270 9990 11 Technical Drawings Standard Bracketry Optional Bracketry Wall Mount Ptz Mount Pole Mount 33mm 1 2 100mm 4 PulseStar x72 PulseStar x32 48 96 PulseStar x24 72mm 52mm 36mm 53mm...

Page 12: ...he product and the hazards involved in accordance with the applicable installation code Please register your Raytec LED Illuminator s for its 5 year warranty by visiting www rayteccctv com products wa...

Reviews: