Raytec Americas:
+1 613 270 9990 • [email protected]
Raytec Ltd reserve the right to change specifications without prior notification or public announcement.
Version 1
www.raytecled.com
1277-D
-0002
Installation Steps
Surge Suppressor Kit (Ordered Separately)
Step 1.
Step 2.
Step 5.
Step 3.
Step 4.
This SPX-BKT-AR-SP-HV kit is intended for use with UL Listed AR luminaire as marked on the luminaire nameplate.
Accessory Package Contents
(Requires SPX-BKT-AR-SP-HV Surge Protector Accessory Kit)
Inspect shipping package and contents to ensure no damage has occurred during
shipping.
Open AR Lens with 7mm hex socket driver. Allow Lens to hang via retention strap.
NOTE: Screws are captive fasteners and will remain attached to the Lens for ease of
reinstall and prevent loss of fasteners.
Close AR lens. Ensure the retention cable is not pinched between AR Head and the
AR Lens. Tighten lens bolts using a 7mm socket or box wrench to 1.7 N-m (15 in-lbs)
in the order designated in the diagram to ensure gasket sealing.
Install provided double-sided tape along side of surge protector. Remove
backing paper and place between mounting points as shown, with tape-side
down. Install retention strap with two M3 fasteners and ensure surge protector
is held tightly in place.
Wire according to wiring instructions on Page 2. Refer to NEC/CEC codes and
follow all applicable local standards.
SPX-BKT-AR-SP-HV
QTY
PART NAME
1
FSP3-480-20KA SURGE PROTECTOR
1
3M VHB TAPE
1
SURGE SUPPRESSOR RETENTION STRAP
2
M3 x 8mm PAN HEAD PHILLIPS MACHINE SCREW
2
M3 FLAT WASHER
Step 3
Step 5
M3 SCREW
5
6
7
8
9
10
11
12
1
2
3
4
SPI-AR