28
Post-processing
In order to obtain a better effect of cleaning, it is
recommended to conduct the ultrasonic washing
with cleaning solvent twice, and 1-2 minutes was
needed every time. Clean solvent should be used
for the second washing.
If the type of resin material will change in the
next task, the printing platform shall be cleaned
with cleaning solvent carefully in order to remove
residual resin.
After the preliminary cleaning, please spray cleaning
solvent on the model. After cleaning, the surface of
the model is dry and free of sticky hands.
Clean printed parts
Preparation: Please fill the spray bottle with IPA or
95% alcohol.
Brush the model in the cleaning tank for preliminary
cleaning.
Clean the printing platform
After the printed parts are removed, use a shovel
blade to clean the surface of the platform, please be
aware that do not damage the platform during the
operation.