CAUTION:
Voltage at the pump
MUST NOT
vary by more than +/- 10% of nameplate voltage. Components
may overheat, causing overload tripping and reduced component life. Consult your power company if this
condition exists.
Note: Use only liquid tight fittings to protect the electronics and motor.
WARNING:
To minimize the risk of severe injury or death, the filter and/or pump should not be subjected
to the piping system pressurization test.
Local codes may require the pool piping system to be subjected to a pressure test. These requirements
are generally not intended to apply to the pool equipment.
However, if the
WARNING
cannot be followed and pressure testing of the complete system must be
done, follow the following guidelines:
1. RELEASE ALL AIR in the system before testing.
2. Water pressure for the test must NOT EXCEED 35 PSI.
3. Water temperature for the test must NOT EXCEED 100° F (38° C).
4. Limit the test to 24 hours. After the test, visually check the system to be sure it is ready for operation.
DO NOT USE COMPRESSED AIR TO PRESSURE TEST OR CHECK FOR LEAKS.
Electrical Installation - continued
Pressure Test
Figure 3
Note: All Dip switches should be in the
OFF position when external controllers
are
not
being used.