background image

15

LIMITED WARRANTY 

SCOPE OF WARRANTY 

Raypak, Inc. (Raypak) warrants to the original owner that the above model gas pool and spa heater (the 

“Heater”) when installed in the contiguous 48 states of the United States of America with a pool or spa by 

a properly licensed installer will be free from defects in materials and workmanship under normal use 

and service for the Applicable Warranty Period. Under this Limited Warranty, Raypak will, at its option, 

repair or furnish a replacement for any defective part of the HEATER. The repair or replacement will be 

warranted for only the unexpired portion of the original Applicable Warranty Period, or the Extended 

Warranty Period, as the case may be. 

EFFECTIVE DATE 

The Effective Date of Warranty coverage is the date of original installation if properly documented; 

otherwise it is 

thirty (30) days after date of purchase, not to exceed one (1) year after date of 

manufacture.

 All Applicable Warranty Periods specified in this Limited Warranty are measured from the 

Effective Date. 

APPLICABLE WARRANTY PERIOD – UNREGISTERED 

If the HEATER is installed with a pool or spa, the Applicable Warranty Period is ninety (90) days from the 

Effective Date, parts and labor, for the HEATER and component parts. 

EXTENDED WARRANTY PERIOD – SERVICE PROFESSIONAL 

If, within 90 days of the Effective Date, (i) the HEATER is installed in a pool or spa at a single family 

residential dwelling by a properly licensed installer (in accordance with applicable state and local laws 

and regulations), and (ii) registered with Raypak (www.raypak.com) with an installation receipt attached 

to such registration, then the Applicable Warranty Period is one (1) year from the Effective Date for the 

HEATER and component parts, but specifically excluding the electrical heating element. The electrical 

heating element will be warranted for a period of 90 days from the Effective Date. 

The HEATER will not 

be eligible for the Extended Warranty Period if installed in a commercial application (hotel, condominium 

or apartment common areas, etc.)

LABOR AND SHIPPING COSTS 

This Limited Warranty covers the reasonable cost of labor for repairs or replacements covered by this 

Limited Warranty, provided that said repairs or replacements are performed by a Raypak designated 

service provider during the Applicable Warranty Period and Raypak has pre-authorized said repair or 

replacement. This Limited Warranty does not cover any travel time or other labor costs. Furthermore, 

unless applicable state law provides otherwise, this Limited Warranty does not cover any shipping costs 

to and from the service provider or to or from the installation site. All of the foregoing costs and expenses 

are your responsibility, unless applicable state law provides otherwise. 

WARRANTY EXCLUSIONS 

This Limited Warranty does 

NOT 

apply: 

1.

if the Heater has been moved from its original place of installation, or if the original owner no

longer owns the property where the original installation was made;

2.

if the Heater is not properly installed with a pool or spa by a qualified licensed installer in

accordance with applicable local codes and ordinances, good trade practices, and the

manufacturer’s installation instructions;

3.

if the rating plate(s) or serial number(s) are altered or removed;

4.

if the Heater is modified in any way, or non-factory authorized accessories or other components

are used in conjunction with the Heater;

5.

to damage, malfunctions or failures resulting from failure to properly install, operate or maintain

the Heater in accordance with the manufacturer’s instructions;

6.

to damage, malfunctions or failures resulting from abuse, act of nature, accident, fire, flood,

freeze, lightning or the like;

7.

to damage, malfunctions or failures resulting from connected system control devices;

8.

to performance problems caused by improper sizing of the Heater or electric service voltage,

wiring or fusing;

16.  WARRANTY

IN REVIEW 

UNCONTROLLED DOCUMENT IF PRINTED 

 

Summary of Contents for E3T ELS 0005

Page 1: ...is manual are for the use of qualified individuals specially trained and experienced in the installation and maintenance of this type of equipment and related system components Installation and service personnel are required by some states to be licensed Persons not qualified shall not attempt to install service or maintain this equipment This manual should be maintained in legible condition and k...

Page 2: ...N 7 11 CONTROL 8 12 REMOTE OPERATION 9 13 TROUBLESHOOTING 11 14 WIRING DIAGRAMS 12 15 ILLUSTRATED PARTS LIST 13 16 WARRANTY 15 Revision 5 reflects the following changes Installation text revised on page 4 Figure 2 Table B and Table C revised on page 6 Wiring Diagram revised on page 11 Illustrated parts List added starting on page 12 Warranty added starting on page 14 IN REVIEW UNCONTROLLED DOCUMEN...

Page 3: ...part B of Part 430 Uniform Test Method for Measuring the Energy Consumption of Pool Heaters 1 WARNINGS Pay Attention to these Terms ADANGER Indicates the presence of immediate hazards which will cause severe personal injury death or substantial property damage if ignored AWARNING Indicates the presence of hazards or unsafe practices which could cause severe personal injury death or substantial pro...

Page 4: ...UCTIONS READ AND FOLLOW ALL INSTRUCTIONS GIVEN IN THIS MANUAL The water in a spa or pool should never exceed 104 F 40 C A water temperature in excess of 104 F 40 C is considered unsafe for all persons Lower water temperatures are recommended for extended use exceeding 10 15 minutes and for young children Excessive water temperatures have a high potential for causing fetal damage during the early m...

Page 5: ...ns All heater models are rated operation ONLY on 240V single phase 60Hz power Heaters are flow activated No Hartford loop is required After tightening both fittings at the water heater start the pump to allow water to run through the spa pool heater for at least 5 10 minutes This process purges all the air from the water lines and must be performed prior to turning on the power at the heater ACAUT...

Page 6: ...appli ances under no circumstances should you attempt to install repair or disassemble this heater without first shutting off all power to the heater directly at the fuse or breaker box AWARNING Serious bod ily injury or death could occur if you ignore shutting off all power to the heater at the fuse or breaker box All wiring wire gauge and circuit protection breakers must comply with the U S Nati...

Page 7: ... DOUBLE POLE BREAKER L2 L1 50 50 DOUBLE POLE BREAKER E1 E1 E2 E1 E2 E1 E2 E3 MODEL ELS 0005 MODEL ELS 0011 MODEL ELS 0018 MODEL ELS 0027 Figure 2 Wire Connection to Circuit Breakers 10 OPERATION Once the heater is installed it can be used year round The user MUST makes sure the pump is not disengaged to allow it to run until the desired temperature setting is reached The heater will function only ...

Page 8: ...40 104 F 4 40 C FOR CELSIUS DISPLAY PUSH BUTTON FOR 2 SECONDS TO TURN OFF PUSH BUTTON ONCE PRESS 2 SECONDS 11 CONTROL Turn the control knob to set your desired temperature When the set tempera ture is reached the heater will go to idle and the elements will not draw power NOTE If the controls and display are active they still draw some power Digital Control Temperature Setting The heater comes wit...

Page 9: ...ate conduit Remote wiring must not be run parallel to high voltage lines For runs of under 30 ft 9 1 m remote wiring should have stranded conductors with a minimum of 22 AWG 600V cable twisting 1 5 to 2 5 3 8 cm to 6 4 cm lay and jacketed For runs over 30 ft 9 1 m the conductors should be a minimum of 20 AWG 600V cable twisting 1 5 to 2 5 3 8 cm to 6 4 cm lay that is shielded and jacketed Maximum ...

Page 10: ...d disconnected from each element 6 10 to 7 11 Ω Delay in energizing elements heater starts heating 1 minute after powering up and sufficient flow is recorded 1 minute 30 secs Turn on flow rate 15 gpm 2 gpm 57 lpm 8 lpm Individual element current at max temp and max flow 31 7 to 40 2 A ECO trip point 140 F 60 C To change temperature setting from Fahrenheit to Celsius Press and hold the knob for 3 s...

Page 11: ...ate temperature in heat rise hr Heater input kw x 410 divided by spa gallonage This does not take into account heat loss due to weather Heat loss from poor weather conditions cold high winds Use an spa cover Defective heating element Call an electrician Spa does not reach temperature Low flow Check filter skimmer basket pump Heating element continuously burning out High input voltage Call the elec...

Page 12: ... CHAMBER CN3 CN4 GND GND L1 L2 L1 L2 L1 L2 FLOW SENSOR 0027 ONLY 240VAC 1 PH 60 Hz SIZE 0027 ONLY 1 3 1 3 1 2 1 2 1 2 WATER OUTLET WATER INLET 1 3 L1 L2 GND 1 3 1 3 CPU TRANSFORMER VH1 VH2 CN1 CN2 CN4 VH3 VH4 CN8 1 2 3 REMOTE CONTROL WIRE F1 250V 1A Y1 AC POWER SUPPLY FLOW SENSOR HIGH LIMIT 2 HIGH LIMIT 1 ELEMENT 2 ELEMENT 1 SIZE 0011 ONLY 150 kOhm 150 kOhm 240VAC 1 PH 60 Hz Figure 6 Wiring Diagra...

Page 13: ...3 15 ILLUSTRATED PARTS LIST 15 7 1 4 5 6 10 8 9 11 12 13 14 3 16 15 1 2 5 6 7 10 9 8 11 12 13 14 4 16 MODELS ELS 0005 and ELS 0011 MODELS ELS 0018 and ELS 0027 IN REVIEW UNCONTROLLED DOCUMENT IF PRINTED ...

Page 14: ...17153F 017153F 017177F 017177F 12 017154F 017154F 017154F 017154F 13 017155F 017155F 017156F 017156F 14 017157F 017157F 017157F 017157F 15 017158F N A 017158F N A 16 Heating Element Includes O Ring Inlet Thermistor Includes O Ring Transformer 240V 60hZ Water Sensor Inlet Outlet High Limit Manual Reset Circuit Board with LED Display Enclosure Hall Effect Sensor Terminal Block Grounding Terminal Tri...

Page 15: ...e Date The HEATER will not be eligible for the Extended Warranty Period if installed in a commercial application hotel condominium or apartment common areas etc LABOR AND SHIPPING COSTS This Limited Warranty covers the reasonable cost of labor for repairs or replacements covered by this Limited Warranty provided that said repairs or replacements are performed by a Raypak designated service provide...

Page 16: ...Heater or component part and to verify warranty coverage at its factory EXCLUSIVE WARRANTY LIMITATION OF LIABILITY THE LIMITED WARRANTY IS THE ONLY WARRANTY GIVEN BY RAYPAK IN CONNECTION WITH THE HEATER AND ITS COMPONENT PARTS NO ONE IS AUTHORIZED TO MAKE ANY OTHER WARRANTIES ON RAYPAK S BEHALF ANY IMPLIED WARRANTIES INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL NOT EXTEND BE...

Page 17: ...Raypak Inc 2151 Eastman Avenue Oxnard CA 93030 805 278 5300 Fax 805 278 5468 Litho in U S A ISO 9001 REGISTERED QUALITY MANAGEMENT SYSTEM www raypak com IN REVIEW UNCONTROLLED DOCUMENT IF PRINTED ...

Reviews: