CONNECTIONS – PLUMBING 

 

IMPORTANT: 

When installing a new water heater to an old or existing system, it is a requirement that the system 

and its equipment be thoroughly inspected and if necessary, drained and flushed with clean fresh water, before the 
new water heater is connected. Failure to do this may cause blockages and/or damage to the water heater which is 
not covered by warranty. 

IF THERE IS ANY DOUBT ABOUT THE SYSTEM, DRAIN AND FLUSH AS A PRECAUTION. 

CONNECTION SIZES 

 

Inlet water connection: RC1½/40 

 

Outlet water connection: RC1½/40 

 

Relief valve connection: RC¾/20 

 

Gas inlet (On/Off Models): RC¾/20 

 

Gas Inlet (Modulating Models: RC1/25 

All  plumbing  work  must  be  carried  out  by  a  qualified  person  and  in  accordance  with  the  National  Plumbing 
Standard AS/NZS 3500.4 and local authority requirements. 

All  gas  work  must  be  carried  out  by  a  qualified  person  and  in  accordance  with  the  Australian  Gas  Installations 
Standard AS 5601 and local authority requirements. 

WATER INLET AND OUTLET 

All  pipe  work  must  be  cleared  of  foreign  matter  before  connection  and  purged  before  attempting  to  operate  the 
water heater. All olive compression fittings must use brass or copper olives. Use thread sealing tape or approved 
thread sealant on all fittings. 

An  isolation  valve  and  non-return  valve  must  be  installed  on  the  cold  water 
line to the water heating system. An acceptable arrangement is shown in the 
diagram opposite for a water heating application. 

A disconnection union must always be provided at the inlet and outlet on the 
water heater to allow for disconnection of the water heater. 

Do not reduce the pipe work size and water heater water connections without 
allowing for friction loss which will occur. Low water flow will cause damage to 
the water heater and system components. 

GAS INLET 

The  gas  connection  is  made  to  the  inlet  of  the  gas  control  (On/Off  Models)  or  pressure  regulator  (Modulating 
Models). The pipe work must be cleared of foreign matter before connection and purged before attempting to light 
the  water  heater.  An  isolation  valve  and  disconnection  union  must  be  used  to allow  servicing  and  removal  of  the 
water heater. 

Refer to the Gas Installations Standard AS 5601 for the correct method of sizing the gas supply  pipe to the water 
heater. 

 WARNING:

 Before pressure testing the gas supply system always isolate and disconnect the water heater after 

the isolating cock to prevent the risk of serious damage to the gas control or pressure regulator. Warranty does not 
cover damage of any nature resulting from failure to observe this precaution. Refer to rating label for gas types and 
pressures. 

Ensure  the  gas  line  is  also  purged  at  the  union  to  the  gas  control  or  pressure  regulator.  If  this  procedure  is  not 
followed, a retry lockout may result on initial start up. 

CAUTION: 

Care is necessary when tightening fittings into the gas control or pressure regulator. The gas control or 

pressure  regulator  casting  may  crack  if  the  fittings  are  over  tightened.  Cracked  castings  are  not  covered  under 
warranty. Damaged gas controls and pressure regulators must be replaced. 

PIPE SIZES 

The pipe sizing for water heating and mechanical heating systems should be carried out by persons competent to 
do so, choosing the most suitable pipe size for each individual application. Reference to the technical specifications 
of the water heater and local regulatory authority requirements must be made. 
 











Summary of Contents for B0200

Page 1: ...stallation Instructions Raypak Water Heaters Models Types B0200 NCO NCM PCO PCM B0280 B0350 B0430 This water heater must be installed and serviced by a qualified person Please leave this guide with a...

Page 2: ...to install this water heater and ask for your Compliance Certificate Warning Upon completion of the installation and commissioning of the water heater leave this guide with the householder or a respo...

Page 3: ...terest CONTENTS 3 ABOUT YOUR WATER HEATER 4 HOW YOUR WATER HEATER WORKS 7 SAVE A SERVICE CALL 8 REGULAR CARE 10 INSTALLATION 11 CONNECTIONS PLUMBING 17 CONNECTIONS ELECTRICAL 20 LOCATION OF CONTROLS 2...

Page 4: ...uitable for the application and will not cause scald injury We recommend and it may be required by regulations that an approved temperature limiting device be fitted into the hot water piping to the b...

Page 5: ...Propane model A Propane model is designed to operate on Propane only The use of Propane Butane mixture such as automotive LPG fuel in a Propane model is unsafe and can cause damage to the water heater...

Page 6: ...ribed on pages 35 HOW LONG WILL THE WATER HEATER LAST The water heater is supported by a manufacturer s warranty refer to page 39 There are a number of factors that will affect the length of service t...

Page 7: ...er heater off when it is not in use The thermostat is fully automatic and only allows the gas control to open when the burner requires gas for heating The thermostat may flash AH alarm high and the cu...

Page 8: ...valve to each shower outlet to reduce water usage Pressure relief valve running Is the relief valve discharging too much water Refer to Pressure Relief Valve Running on page 9 Thermostat setting Ensu...

Page 9: ...indicate the mains water pressure sometimes rises above the designed pressure of the water heater Ask your installing plumber to fit a pressure limiting valve WARNING Never replace the relief valve w...

Page 10: ...failing Warning Exercise care to avoid any splashing of water as water discharged from the drain line will be hot Stand clear of the drain line s point of discharge when operating the valve s lever If...

Page 11: ...ure relief valve may be supplied inside the water heater casing This kit must be removed before the water heater is operated READ THESE INSTRUCTIONS IN FULL INSPECTION OF EQUIPMENT Check the water hea...

Page 12: ...ght diverter before changing direction The flue design and installation must comply with AS 5601 NOTE Reduction of the flue diameter or alteration to the draft diverter may void the water heater warra...

Page 13: ...ase the base material MUST be solid and filled in e g if steel mesh decking is used a suitable plate material must be installed to fill in the perforations to prevent excessive drafts entering the wat...

Page 14: ...ng kPa 700 550 700 550 Mechanical Heating kPa Minimum Supply Pressure System water temperatures up to 65 C kPa 70 70 System water temperatures above 65 C kPa 120 120 Maximum Supply Pressure with ECV f...

Page 15: ...nches off before this valve or from another cold water line in the premises then a pressure limiting valve of an equal pressure setting may be required prior to the temperature limiting device REDUCIN...

Page 16: ...ut kW 44 62 76 94 Propane Gas Input MJ h 185 261 323 396 Output kW 41 58 72 88 Electrical Rating 240 V 50 Hz Power W 50 50 50 50 Current A 0 21 0 21 0 21 0 21 Weight empty Kg 91 93 103 107 Flue Connec...

Page 17: ...pipe work size and water heater water connections without allowing for friction loss which will occur Low water flow will cause damage to the water heater and system components GAS INLET The gas conne...

Page 18: ...g to the connection on the inlet outlet header then screw the relief valve onto the other end of the elbow Seal the treads using Teflon tape never hemp A drain line must be installed in accordance wit...

Page 19: ...stem should be provided with manual bleed points or fitted with automatic air vents The design of the system must be such that the water heater is provided with adequate water flow and pressure at all...

Page 20: ...hermostat setting requirements with the householder or responsible officer Refer to Temperature Control on page 30 INTERMITTENT PUMP OPERATION For applications utilising intermittent pump operation an...

Page 21: ...On Off models cannot be connected to a building management system CONTROL PANEL ACCESS To access the electrical enclosure Remove the Philips head screw from the bottom of the front panel Remove the fr...

Page 22: ...CONNECTIONS ELECTRICAL 22 WIRING DIAGRAM ON OFF MODELS...

Page 23: ...CONNECTIONS ELECTRICAL 23 WIRING DIAGRAM MODULATING MODELS...

Page 24: ...PTION MECHANICAL HEATING SYSTEMS NOTE When connecting additional controls the relays and timers etc must be located in an additional enclosure NOT fitted within the water heater For outdoor installati...

Page 25: ...ff type water heaters are fitted with a Honeywell SV9605 smart valve This gas control incorporates the ignition electronics and provides the gas supply to the pilot and main burners Modulating Models...

Page 26: ...loose fitting long sleeved clothing or disposable overalls Wear gloves and eye protection Consult Occupational Health and Safety Authorities for any further information AFTER HANDLING Rinse any expos...

Page 27: ...sure that the main gas isolation valve is closed OPERATIONAL CHECKS Turn on the water heater and circulation pump and verify the flow switch operation if fitted refer to To Turn on the Water Heater on...

Page 28: ...at the inlet to the water heater Plug in the power supply cord at the power outlet Switch on the electrical supply at the power outlet to the water heater NOTE If the water heater is correctly instal...

Page 29: ...label refer to Location of Controls on page 25 Turn off the water heater Replace the cap on the pressure regulator adjuster Disconnect the manometer and replace the pressure tap screw and washer Chec...

Page 30: ...ach folder indicated by the relevant label just press the SET key once You can now scroll through the contents of each folder modify it or use its functions If you do not use the keyboard for over 15...

Page 31: ...TEMPERATURE CONTROL 31...

Page 32: ...at Cool mode HC H C H Ont Oft Delay time relay on dOn sec 0 250 0 Delay time relay off dOF min 0 250 0 dbi min 0 250 0 Delay time at start up OdO min 0 250 0 dis Key pad lock LOC y n n Password PA1 nu...

Page 33: ...d in a well pocket fitted in the outlet header and senses the temperature of the water leaving the water heater The high limit temperature setting is adjusted by removing the front cover loosen one Ph...

Page 34: ...ilot flame Yellow flames indicate some restriction of the combustion air openings or incorrect burner gas pressure setting A bright orange luminous flame is not normal and can cause sooting under prol...

Page 35: ...elief valve In a scaling water supply calcium carbonate is deposited out of the water onto any hot metallic surface Where the saturation index exceeds 0 80 warranty does not apply to a copper heat exc...

Page 36: ...36 This page is intentionally blank...

Page 37: ...37 This page is intentionally blank...

Page 38: ...38 This page is intentionally blank...

Page 39: ...led site shall be the owner s responsibility 2 5 Where the water heater is installed in a position that does not allow safe or ready access the cost of that access including the cost of additional mat...

Page 40: ...ish to make a claim under this warranty you need to a Contact Rheem on 131031 and provide owner s details address of the water heater a contact number and date of installation of the water heater or i...

Reviews: