PROBLEM CAUSE SOLUTION
Harmonics, or whining noise
U.G. inoperative................................... Check movement by putting in hot water (110°F or higher).
If no movement, replace.
*Debris or restriction in system............ Locate the restriction and remove. Flush system and clean.
*Debris in gas line................................ Remove debris or blow out gas line.
Low flow............................................... Scale forming in heat exchanger - clean heat exchanger and
check pool pH and total alkalinity.
Heater going on and off
Dirty filter.............................................. Clean or replace filter.
continuously
Low water level in pool........................ Raise water level.
External bypass setting out of
adjustment............................................ Adjust bypass.
*Pressure switch out of adjustment..... Adjust pressure switch.
Liming or scale forming in
Pool water............................................ See Water Chemistry on page 2.
exchanger
Bypassing too much water................... Inspect bypass for movement, if no movement, replace.
U.G. not functioning............................. Replace if no movement when heated.
Sooting
High flow rates..................................... Reduce by adding manual bypass valve.
Adjust manual bypass valve until heater outlet water
temperature is between 105°F and 110°F.
U.G. Inoperative................................... Check movement by putting in hot water (110°F or higher).
If no movement, replace.
*Air starvation....................................... Refer to installation instructions.
*Improper venting................................ Follow recommended installation instructions.
*Insects or debris clogging
burner intake ports............................. Clean burners.
Pilot outage or
Low gas pressure................................ Adjust gas pressure.
“Weak Flame” signal
Restricted/dirty pilot............................. Clean pilot and/or electrode.
Weak pilot generator............................ Replace pilot.
Yellow lazy flame
Low gas pressure................................ Adjust gas pressure.
*Insects or debris clogging
burner intake ports............................... Clean burners.
Outer jacket very hot
*Broken refractory caused by
(paint blistered)
shipping damage or improper
combustion......................................... Replace refractory panels.
Excessive sooting of heat exchanger.. Determine cause of sooting & correct.
Takes too long to heat
Under-sized heater............................... Calculate heating capacity of heater:
pool or spa
Htr. output(BTUH)
Pool gallonage x 8.33 or refer to heater sizing chart.
This does not take into account heat loss due to weather.
Filter not running long enough............. Reset time clock.
Dirty filter.............................................. Clean filter.
Gas line or meter undersized............... Refer to installation instructions.
Leaking at well
Overacid............................................... Replace well and maintain proper water chemistry.
Leaking at heat exchanger
Overacid............................................... Replace heat exchanger and maintain proper water chemistry.
Gasket brittle and leaking -
Heater running after pump shuts off.... See Pressure Switch Adjustment.
(overheated)
Refractory damage.............................. Replace refractory.
Sooted heater....................................... Determine cause of sooting and correct.
Combustion fan not running
Fan relay.............................................. Replace fan relay.
“Fan 5 min Delay” signal or
Fan........................................................ Loose connection or failed motor.
“Fan Lockout” signal
Burned motor ...................................... Incorrect wiring, replace blower.
Air pressure switch............................... Replace air switch.
SECTION 5 - TROUBLESHOOTING
* Indicates symptom which usually occurs on initial start-up.
Summary of Contents for 336A
Page 28: ...28 WIRING DIAGRAM MILLIVOLT MECHANICAL THERMOSTAT...
Page 29: ...29 WIRING DIAGRAM ATMOSPHERIC...
Page 30: ...30 WIRING DIAGRAM LO NOx...
Page 48: ...48 19 M 20 M 22 M 24 M 23 M 21 M 22 M ATMOSPHERIC HEATERS...
Page 49: ...49 16 M 17 M 19 M 21 M 20 M 18 M 19 M LO NOx HEATERS...
Page 50: ...50...
Page 52: ...52 ATMOSPHERIC HEATERS...
Page 53: ...53 ATMOSPHERIC HEATERS...
Page 54: ...54 LO NOx HEATERS...
Page 55: ...55 LO NOx HEATERS...